Trojan 27TMX 12V 105Ah Flooded Deep Cycle with Wingnut Terminal Battery 27TMX

Trojan 27TMX 12V 105Ah Flooded Deep Cycle with Wingnut Terminal Battery 27TMX

Regular price $232.50
LESS THAN 50
Leave a Review

Trojan 27TMX 12V 105Ah Flooded Deep Cycle with Wingnut Terminal Battery 27TMX

Trojan 27TMX 12V 105Ah Flooded Deep Cycle with Wingnut Terminal Battery 27TMX

Available
MPN No: 27TMX
Regular price $232.50

1
2
3
4
5
6

Shipping calculated at checkout. About shipping

delivery icon
Expected ship date Nov 28 - Dec 05

SPEC_27TMX_USSS
Data Sheet: Trojan 27TMX

U.S. Warehouse

Trusted by Thousands

Expert U.S. Support

View full details
Regular price $232.50

Trojan 27TMX 12V 105Ah Flooded Deep Cycle Battery with Wingnut Terminals

12V Deep Cycle Battery | 105Ah at 20-Hour Rate | Group 27 | Flooded Lead Acid | T2 Technology | Wingnut Terminals

The Trojan 27TMX 12V Deep Cycle Battery delivers dependable energy storage for applications requiring repeated charging and discharging. Built with Trojan's T2 Technology, this flooded lead-acid battery offers a rated capacity of 105Ah at the 20-hour discharge rate in a standard BCI Group 27 format.

Designed for deep cycle service, the 27TMX is a practical choice for compatible renewable energy systems, RV electrical systems, marine house battery applications, and other auxiliary power installations.

The battery features a durable maroon polypropylene case, serviceable flooded construction, and wingnut terminals for connecting compatible battery cables.

Its compact Group 27 dimensions make it suitable for installations where space is limited but reliable deep cycle energy storage is required.

Key Features and Benefits

  • 105Ah Deep Cycle Capacity: Rated at the 20-hour discharge rate for dependable energy storage.
  • 12V Nominal Voltage: Compatible with appropriately designed 12V battery systems and higher-voltage banks using series connections.
  • Trojan T2 Technology: Proprietary battery technology developed for deep cycle performance.
  • Flooded Lead-Acid Construction: Serviceable battery design for applications where periodic maintenance is practical.
  • BCI Group 27 Size: Standardized battery dimensions for compatible enclosures and battery trays.
  • Wingnut Terminals: Convenient threaded connections for compatible battery cable terminals.
  • Durable Polypropylene Case: Designed for demanding battery applications.
  • Deep Cycle Performance: Engineered for repeated charging and discharging rather than primarily for engine starting.
  • Flexible System Integration: Can be used in appropriately designed battery banks with compatible charging and inverter equipment.

Trojan T2 Technology

The Trojan 27TMX incorporates the manufacturer's T2 Technology in a flooded deep cycle battery design.

Built for applications requiring repeated energy cycling, the battery supports dependable DC power storage when used with compatible equipment and maintained according to Trojan's charging and service recommendations.

Designed for Deep Cycle Applications

Unlike batteries primarily intended for starting engines, the Trojan 27TMX is designed for applications where electricity is stored and discharged over extended periods.

Its 12V nominal voltage and Group 27 footprint make it suitable for a variety of stationary and mobile auxiliary power systems.

Common Applications

  • Small off-grid solar battery systems.
  • RV and camper house battery banks.
  • Marine auxiliary and house power systems.
  • Remote DC power applications.
  • Deep cycle renewable energy storage.
  • Compatible auxiliary battery installations.

Battery Capacity and Energy Storage

The Trojan 27TMX provides different amp-hour capacities depending on the discharge rate.

At the standard 20-hour discharge rate, the battery delivers 105Ah, equivalent to approximately 1.26kWh of nominal energy based on its 12V rating.

At the slower 100-hour discharge rate, the manufacturer lists a capacity of 117Ah and an energy rating of 1.40kWh.

Actual usable energy depends on discharge current, temperature, depth of discharge, battery condition, and system efficiency.

Charging and Maintenance

The Trojan 27TMX requires charging equipment configured for flooded lead-acid battery chemistry.

Trojan provides the following charging voltage recommendations for a 12V battery at 77°F (25°C):

  • Absorption Charge: 14.8V.
  • Float Charge: 13.2V.
  • Equalization Charge: 15.5V, performed only according to manufacturer instructions.

Charging voltage must be adjusted appropriately for battery temperature. Routine flooded battery maintenance, including electrolyte inspection and watering when required, is essential for proper operation.

Safety Note: Never install or charge flooded lead-acid batteries in a sealed or unventilated compartment. Improper charging can damage the battery and shorten its service life.

Product Specifications

Specification Details
General Specifications
Manufacturer Trojan Battery Company
Model 27TMX
MPN 27TMX
Battery Type Flooded / Wet Lead-Acid Deep Cycle
Technology Trojan T2 Technology
Nominal Voltage 12V DC
BCI Group Size 27
Terminal Configuration Wingnut Terminal (WNT)
Vent Type POD vent
Case Color Maroon
Case Material Polypropylene
Integrated Watering System Not included
Capacity and Performance
Capacity at 5-Hour Rate 85Ah
Capacity at 10-Hour Rate 97Ah
Capacity at 20-Hour Rate 105Ah
Capacity at 100-Hour Rate 117Ah
Nominal Energy at 20-Hour Rate Approximately 1.26kWh (calculated)
Manufacturer Energy Rating 1.40kWh at 100-hour rate
Reserve Capacity at 25A 175 minutes
Reserve Capacity at 75A 45 minutes
Physical Specifications
Length 12.72 in (323 mm)
Width 6.60 in (168 mm)
Height Including Terminals 9.24 in (235 mm)
Weight 55 lbs (25 kg)
Terminal Type WNT — Wingnut
Terminal Bolt Size 5/16 in
Terminal Torque 95–105 in-lb (11–12 Nm)
Wingnut Terminal Height 0.95 in (24 mm)
Charging Specifications at 77°F / 25°C
Absorption Charge Voltage 14.8V
Float Charge Voltage 13.2V
Equalization Charge Voltage 15.5V
Temperature Compensation 0.028V per cell per 10°F (5.55°C), adjusted relative to 77°F
Operating Conditions
Operating Temperature -4°F to 113°F (-20°C to 45°C)
Cold Weather Recommendation Maintain greater than 60% state of charge below 32°F (0°C)
Self-Discharge Rate 5–15% per month depending on storage temperature
Ventilation Requirement Do not install or charge in sealed or non-ventilated compartments

Battery Bank Configurations

The Trojan 27TMX can be used in properly designed series or parallel battery configurations.

  • 12V System: 1 battery — 105Ah at the 20-hour rate.
  • 24V System: 2 batteries in series — 105Ah, approximately 2.52kWh nominal energy.
  • 48V System: 4 batteries in series — 105Ah, approximately 5.04kWh nominal energy.

Additional parallel strings can increase total battery bank capacity when properly designed. Follow Trojan's battery matching, wiring, and charging recommendations.

Note: Energy figures are nominal calculations. Usable energy is lower and depends on operating conditions and selected depth of discharge.

Installation and Safety Considerations

  • Use a compatible flooded lead-acid battery charger or solar charge controller.
  • Install the battery in a properly ventilated location.
  • Maintain electrolyte levels according to Trojan's maintenance instructions.
  • Use properly sized battery cables and suitable overcurrent protection.
  • Follow the manufacturer's terminal torque recommendations.
  • Use appropriate battery enclosures or trays designed for Group 27 batteries.
  • Avoid sparks, flames, and other ignition sources near batteries.
  • Use suitable personal protective equipment when handling or servicing flooded batteries.

Frequently Asked Questions

What is the capacity of the Trojan 27TMX?

The Trojan 27TMX is rated at 105Ah at the 20-hour discharge rate. The manufacturer also lists 117Ah at the 100-hour rate.

How much energy does this battery store?

At the 20-hour rate, 12V × 105Ah equals approximately 1.26kWh of nominal energy. Trojan lists 1.40kWh at the 100-hour discharge rate.

Is the Trojan 27TMX a lithium or AGM battery?

No. The Trojan 27TMX is a flooded wet-cell lead-acid deep cycle battery.

Can the Trojan 27TMX be used with solar panels?

Yes. It can be used in a compatible solar energy storage system with an appropriately configured charge controller and other required electrical equipment. Solar panels should not be connected directly to the battery without suitable charging control.

Does this battery require maintenance?

Yes. As a flooded lead-acid battery, it requires periodic electrolyte checks, watering when necessary, and proper charging and ventilation.

What type of terminals does this battery have?

This listing specifies the wingnut terminal (WNT) configuration, which uses a 5/16-inch bolt connection.

How many batteries are needed for a 48V system?

Four 12V batteries connected in series provide a nominal 48V battery bank. System compatibility and battery bank configuration must be verified before installation.

Can this battery be installed inside a house?

Flooded lead-acid batteries must not be installed or charged in sealed or unventilated spaces. Any indoor installation requires a suitable battery area with ventilation and applicable safety provisions.

What is the weight of the Trojan 27TMX?

The manufacturer lists a weight of approximately 55 lbs (25 kg).