Fronius Primo 7.6kW 208/240V Single-Phase Solar Inverter, Lite – 4210061801
MPN No: 4,210,061,801
Expected ship date Nov 16 - 23
In Stock
$2,145.00
You will not be able to undo this action.

U.S. Warehouse
Trusted by Thousands
Expert U.S. Support

4,210,061,801
MPN No: 4,210,061,801
Expected ship date Nov 16 - 23
In Stock
$2,145.00
7,600W AC Output | 208/240V | Single-Phase | Dual MPPT
The Fronius Primo 7.6-1 Lite is a high-efficiency, single-phase grid-tied solar inverter designed for residential and compatible light commercial photovoltaic installations. Featuring Fronius SnapINverter technology, two independent MPPT trackers, integrated DC disconnect, and advanced electrical protection, the Primo Lite delivers reliable DC-to-AC conversion with an installation-friendly design.
Manufacturer Part Number: 4,210,061,801
Product Configuration: Fronius Primo 7.6-1 Lite, 208/240V.
Not Included: Solar panels, battery storage, racking, external rapid shutdown devices, and optional monitoring or communication accessories.
The Fronius Primo 7.6-1 Lite is designed to convert electricity generated by solar panels into grid-compatible AC power for residential and light commercial solar systems.
With 7,600W of rated AC output and support for 208V and 240V single-phase connections, the Primo Lite offers flexible integration with compatible electrical service configurations.
Its two independent maximum power point trackers help optimize solar energy production from separate PV strings. This is especially useful for installations with different roof orientations or array configurations.
The inverter's transformerless design delivers up to 96.9% maximum efficiency, while Fronius active cooling helps manage operating temperatures and support dependable performance.
Built around Fronius SnapINverter technology, the Primo Lite separates the mounting and connection area from the inverter's power electronics. This approach simplifies installation, wiring access, and future servicing.
The Lite configuration is particularly suited for projects where integrated Fronius Datamanager monitoring is not required or where compatible communication equipment will be provided separately.
The Fronius Primo 7.6-1 Lite includes two independent maximum power point trackers designed to optimize energy harvest from connected PV strings.
Solar string sizing must account for the selected panels' operating voltage, open-circuit voltage, temperature coefficients, current ratings, and the inverter's exact DC voltage configuration.
Important DC Voltage Note: The Fronius Primo Lite datasheet specifies a standard maximum DC input voltage of 600V, with a 1,000V option identified separately. Do not assume this particular MPN includes the 1,000V option without confirming its exact factory configuration.
Fronius SnapINverter technology is designed to make solar inverter installation and servicing more straightforward.
The inverter uses a two-part construction that separates the connection area from the power electronics.
This architecture can reduce service complexity and make the Primo Lite an attractive choice for solar installers familiar with the Fronius platform.
The primary difference is the integrated communication and monitoring equipment.
The standard Fronius Primo configuration includes a Datamanager communication package for supported network connectivity and online monitoring functions.
The Primo Lite configuration does not include that integrated Datamanager package.
Monitoring Note: The Lite designation does not mean the inverter has built-in Wi-Fi monitoring. Fronius Solar.web connectivity and certain advanced monitoring functions require compatible additional communication equipment.
The Fronius Primo 7.6-1 Lite incorporates multiple protection features designed for properly installed grid-connected solar systems.
Additional rapid shutdown devices, disconnects, overcurrent protection, or other equipment may be required depending on the installation and applicable electrical code.
Fronius lists a recommended PV array power range of approximately 6.1kW to 11.7kW DC for the Primo Lite 7.6-1.
This range supports solar array designs with DC capacity above the inverter's 7.6kW AC output, allowing appropriate DC oversizing to help improve energy harvest across varying sunlight conditions.
Actual allowable solar array size depends on the inverter's voltage configuration, MPPT current limits, panel specifications, installation temperatures, and local electrical requirements.
| Specification | Details |
|---|---|
| Manufacturer | Fronius |
| Product Series | Primo Lite |
| Model | Primo 7.6-1 Lite |
| Manufacturer Part Number | 4,210,061,801 |
| Inverter Type | Grid-Tied String Inverter |
| Output Phase | Single-Phase |
| Rated AC Output | 7,600W / 7,600VA |
| Nominal AC Voltage | 208V / 240V |
| Nominal Grid Frequency | 60Hz |
| Maximum Continuous AC Current at 208V | 36.5A |
| Maximum Continuous AC Current at 240V | 31.7A |
| Manufacturer AC Breaker Size at 208V | 50A |
| Manufacturer AC Breaker Size at 240V | 40A |
| Maximum Efficiency | 96.9% |
| CEC Efficiency | 96.0% |
| Recommended PV Array Power | 6.1kW to 11.7kW DC |
| Number of MPPT Trackers | 2 |
| Maximum Usable DC Current per MPPT | 18A |
| Maximum Combined Usable DC Current | 36A |
| Maximum PV Short-Circuit Current per MPPT | 27A |
| DC Start-Up Voltage | 80V |
| Nominal DC Input Voltage | 420V |
| Standard DC Operating Voltage Range | 80V to 600V |
| Standard MPPT Voltage Range | 250V to 480V |
| Standard Maximum DC Input Voltage | 600V |
| Optional Maximum DC Input Voltage | 1,000V, configuration dependent |
| Power Factor Range | 0.85 to 1, Inductive / Capacitive |
| Total Harmonic Distortion | Less Than 5% |
| Inverter Topology | Transformerless |
| Cooling | Variable-Speed Fan / Active Cooling |
| Enclosure Rating | NEMA 4X |
| DC Disconnect | Integrated |
| Arc Fault Protection | Integrated AFCI |
| Ground Fault Protection | Integrated |
| Anti-Islanding | Integrated Grid Protection |
| Rapid Shutdown | Supports Compliant System Designs with Required Equipment |
| Integrated Datamanager | Not Included in Lite Configuration |
| Monitoring | Optional Compatible Communication Equipment Required |
| Mounting System | Fronius SnapINverter |
| Nominal Operating Mode | Grid-Tied |
| Battery Storage Included | No |
| Solar Panels Included | No |
The Fronius Primo 7.6-1 Lite is a 7.6kW single-phase grid-tied solar string inverter designed to convert DC electricity from solar panels into 208V or 240V AC electricity. It features dual MPPT trackers, SnapINverter technology, and integrated electrical protection.
The primary difference is integrated communications. The standard Primo includes Datamanager functionality, while the Lite configuration is supplied without the integrated Datamanager package. The Lite designation does not reduce the inverter's 7.6kW rated output.
No integrated Datamanager is included in the Lite configuration. Fronius Solar.web monitoring and network communication require compatible additional equipment. Verify the appropriate Datamanager accessory before purchasing.
The Fronius Primo 7.6-1 Lite is a single-phase solar inverter. It supports compatible 208V and 240V AC grid connections. Confirm the site's electrical service configuration before installation.
Yes. Fronius specifies 7,600VA maximum AC output at both 208V and 240V. The maximum continuous AC output current is 36.5A at 208V and 31.7A at 240V.
The number of solar panels depends on their wattage, voltage, current, and string configuration. Fronius lists a recommended array power range of approximately 6.1kW to 11.7kW DC. Final string sizing must remain within the inverter's electrical limits.
Potentially. Both 400W and 450W modules may be suitable when the complete string configuration meets the inverter's MPPT voltage range, maximum input voltage, usable input current, and short-circuit current requirements. Panel wattage alone does not establish compatibility.
Dual MPPT means the inverter has two independent maximum power point trackers. Each tracker can optimize a connected PV input independently, which can help with arrays that have different orientations or operating characteristics.
The Primo Lite datasheet specifies a standard maximum DC input voltage of 600V, with a 1,000V option identified separately. Confirm the exact voltage configuration of the supplied unit before designing PV strings.
The manufacturer lists a maximum efficiency of 96.9% and a CEC weighted efficiency of 96.0% for the Primo Lite 7.6-1.
SnapINverter technology separates the inverter's wall-mounted connection area from its power electronics. This design simplifies wiring access, installation, and servicing because the power stage can be removed while the connection area remains mounted.
Yes. The Primo Lite has a NEMA 4X enclosure designed for approved indoor and outdoor applications. Follow Fronius requirements for mounting location, ventilation, clearances, and environmental conditions.
Yes. The inverter includes an integrated DC disconnect. Additional disconnect equipment may still be required depending on the system design and applicable electrical codes.
Yes. The Fronius Primo platform includes integrated arc fault circuit interruption functionality. All required electrical protections must still be evaluated as part of the complete installation.
The inverter supports rapid shutdown system designs, but additional equipment may be required to meet current rooftop rapid shutdown requirements. The complete installation must be evaluated against the applicable electrical code.
No. The Primo Lite is a grid-tied solar string inverter, not a hybrid battery inverter. Battery storage requires a separately designed compatible storage system and associated equipment.
No. The inverter is designed for grid-connected operation and shuts down when the utility grid is unavailable. It does not independently provide backup electricity during an outage.
Potentially. The Primo Lite may be suitable for a new installation or an inverter replacement if the existing solar array, AC connection, rapid shutdown equipment, and utility requirements are compatible. A qualified installer should evaluate the system before replacement.
The Fronius Primo Lite datasheet lists a 40A AC breaker at 240V and a 50A AC breaker at 208V. Final overcurrent protection, conductor sizing, and installation requirements must be determined according to the manufacturer's instructions and applicable electrical codes.
Fronius documentation for the Primo platform identifies UL 1741 and other applicable safety and interconnection standards. Confirm the exact supplied model's current listing and utility approval status, particularly where newer IEEE 1547-2018 or UL 1741 SB requirements apply.
No. This product listing is for the Fronius Primo 7.6-1 Lite inverter. Solar panels, batteries, racking, external rapid shutdown equipment, and optional monitoring accessories are not included.
Yes, subject to the manufacturer's design limits. Fronius lists a recommended PV array power range of 6.1kW to 11.7kW DC. The inverter's AC output remains limited to 7.6kW, and all DC voltage and current limits must be respected.
Product information is based on published Fronius Primo Lite technical documentation. Specifications may vary by production version, voltage option, certification status, and regional configuration. Verify the exact MPN, included accessories, installation requirements, and applicable utility approval before purchasing or installing.