Sale

3.6kW Off Grid Solar Kit with Sol-Ark 5K & Discover 5.12kWh Heated Lithium Battery

3.6kW Off Grid Solar Kit with Sol-Ark 5K & Discover 5.12kWh Heated Lithium Battery

Regular price $5,535.00 -10% $4,949
11% OFF
New
LESS THAN 50
Leave a Review

3.6kW Off Grid Solar Kit with Sol-Ark 5K & Discover 5.12kWh Heated Lithium Battery

3.6kW Off Grid Solar Kit with Sol-Ark 5K & Discover 5.12kWh Heated Lithium Battery

Available
MPN No: 3.6kW Off Grid Solar Kit
Regular price $5,535.00 -10% $4,949

1
2
3
4
5
6

Shipping calculated at checkout. About shipping

delivery icon
Expected ship date Nov 28 - Dec 05

Data sheet: Discover 5kWh Battery 48-48-5120-H
Discover 5kWh Battery Manual
Product Guide: Discover 5kW Battery
Data Sheet: Philadelphia 450W Solar Panel MNB108(HCBF)-450W
Data Sheet: Sol-Ark 5kW 5K-1P-N

U.S. Warehouse

Trusted by Thousands

Expert U.S. Support

View full details
Regular price $5,535.00 -10% $4,949

3.6kW Off Grid Solar Kit with Sol-Ark 5K & Discover 5.12kWh Battery

What's Included in the Kit

  • 8 × Philadelphia Solar 450W N-Type Bifacial Solar Panels
    MPN: PS-MNB108(HCBF)-450W
  • 1 × Sol-Ark 5K Single-Phase Hybrid Solar Inverter
    MPN: 5K-1P-N
  • 1 × Discover Energy AES RACKMOUNT 5.12kWh Heated LiFePO₄ Battery
    MPN: 48-48-5120-H

Off Grid Solar System with Hybrid Inverter and Heated Lithium Battery Storage

N-Type Bifacial Solar Panels | Sol-Ark Hybrid Inverter | Discover Heated Lithium Battery | Off Grid Solar Power | Expandable Energy Storage

Build a residential off grid solar system with this solar kit featuring Philadelphia Solar bifacial panels, a Sol-Ark hybrid inverter, and a Discover Energy AES RACKMOUNT heated lithium battery.

Designed for homeowners exploring off grid solar power, energy independence, and residential battery storage, this equipment bundle combines efficient solar generation with hybrid power conversion and rechargeable lithium battery technology.

The Philadelphia Solar panels generate electricity from available sunlight, while the Sol-Ark inverter manages photovoltaic conversion and supported battery charging functions. The Discover Energy battery provides lithium iron phosphate storage with integrated heating, advanced battery management, and a rackmount design.

Whether you're planning a residential off grid solar installation, expanding an existing solar battery system, or designing backup power for essential household loads, this kit provides the primary components for a customized solar energy solution.

Important: This is a solar equipment bundle, not a complete ready-to-install system. Independent off grid operation requires confirmed inverter-battery compatibility, appropriate electrical equipment, and site-specific system design.

Key Features and Benefits

  • Solar generation and battery storage: Combines photovoltaic modules, hybrid power conversion, and rechargeable energy storage.
  • Off grid solar applications: Provides the primary components used in properly designed independent solar power systems.
  • N-type bifacial solar technology: Supports efficient solar production with the potential for additional rear-side generation.
  • Sol-Ark hybrid inverter: Provides solar input management, battery charging, and supported grid-interactive functions.
  • Heated lithium battery: Integrated heating helps support battery charging during colder conditions.
  • LiFePO₄ chemistry: Provides a cobalt-free energy storage solution with favorable thermal stability.
  • Advanced battery management: Discover's BMS monitors operating conditions and supports protective charging controls.
  • Solar self-consumption: Supports storing generated electricity for later household use.
  • Expandable battery platform: The AES RACKMOUNT family supports compatible multi-battery configurations.
  • LYNK connectivity: Supports integration with compatible inverter systems using appropriate communication equipment.
  • Potential backup applications: Can form part of a professionally designed essential-load backup system when compatibility and installation requirements are satisfied.

Philadelphia Solar N-Type Bifacial Solar Panels

Philadelphia Solar's NEXUS modules feature N-type monocrystalline half-cell technology designed for efficient photovoltaic generation and dependable outdoor performance.

The bifacial design allows sunlight to reach the solar cells from both the front and rear surfaces, creating the potential for additional energy production from reflected light.

These modules are suitable for properly designed residential rooftop and ground-mounted solar installations, including compatible off grid solar systems.

Solar Panel Features

  • Efficient N-type monocrystalline cell technology.
  • Bifacial solar energy generation.
  • Half-cell architecture designed to reduce mismatch losses.
  • Durable construction for outdoor applications.
  • Anti-PID design features.
  • Manufacturer-backed product and power performance warranties.

Benefits of Bifacial Solar Technology

Bifacial solar panels can collect direct sunlight and reflected light reaching the rear surface of the module.

Rear-side generation can be particularly beneficial for elevated arrays, ground-mounted installations, and locations with reflective surfaces beneath the modules.

Actual energy production depends on sunlight conditions, mounting height, shading, surface reflectivity, and installation design.


Sol-Ark 5K Hybrid Solar Inverter

The Sol-Ark hybrid inverter provides central power conversion and energy management functions for this solar and battery storage package.

It accepts compatible photovoltaic inputs, supports battery charging, and provides AC electricity for appropriately configured electrical loads.

The inverter also offers supported grid-interactive operating modes, monitoring connectivity, and generator integration features.

Hybrid Inverter Features

  • Integrated MPPT control: Helps optimize energy production from compatible solar strings.
  • Hybrid solar operation: Supports photovoltaic generation and battery integration.
  • Battery charging: Provides configurable charging functions for supported battery systems.
  • Grid-interactive capabilities: Supports appropriate utility-connected solar applications.
  • Energy management: Provides configurable operating modes for solar generation and storage.
  • Monitoring connectivity: Supports compatible network monitoring.
  • Generator integration: Provides supported generator control functionality.
  • Electrical protection: Includes inverter safety and electrical monitoring features.

Residential Energy Management

With an approved battery configuration, the Sol-Ark inverter can help manage how generated solar electricity is used, stored, and delivered to connected loads.

Homeowners can configure supported operating modes around their energy priorities and intended electrical applications.

Important: The specified Sol-Ark inverter provides nominal 120V single-phase AC output. It is not a conventional 120/240V split-phase whole-home inverter. Its suitability for household electrical service and backup circuits must be confirmed during system design.


Off Grid Solar System Applications

An off grid solar system generates electricity using solar panels and stores available energy in batteries for use when sunlight is limited or unavailable.

This off grid solar kit combines three primary components commonly used in independent solar energy systems: photovoltaic panels, a hybrid inverter, and rechargeable lithium battery storage.

When properly designed and configured with compatible equipment, an off grid solar system can supply selected electrical loads without relying on continuous utility power.

Benefits of an Off Grid Solar System

  • Greater energy independence: Generate and store electricity for use without relying exclusively on utility power.
  • Solar battery storage: Store available solar energy for evening use and periods of reduced sunlight.
  • Hybrid inverter technology: Manage solar generation and compatible battery charging through one inverter platform.
  • Heated lithium battery: Helps support battery charging in colder installation environments.
  • Expandable storage: Plan for additional compatible battery capacity as energy needs increase.
  • Flexible applications: Supports appropriately designed residential solar storage, independent power, and backup energy projects.

Planning Your Off Grid Solar Installation

A successful off grid solar system requires careful consideration of daily electricity consumption, peak electrical loads, seasonal sunlight availability, and battery storage requirements.

The solar array must generate sufficient electricity for the intended loads, while the battery bank must provide adequate stored energy during periods without sunlight.

For year-round off grid living, additional solar panels, battery capacity, or generator support may be necessary.

This equipment bundle is best evaluated as the foundation for a customized off grid solar system rather than a guaranteed whole-home independent power solution.


Discover Energy AES RACKMOUNT Heated Lithium Battery

The Discover Energy AES RACKMOUNT heated battery provides rechargeable lithium iron phosphate energy storage for compatible residential solar and stationary energy systems.

Its compact rackmount design combines advanced battery management, integrated heating, and high-current capability in a modular storage platform.

The battery is designed for residential off grid solar and backup energy applications when used within an approved system configuration.

Discover Battery Features

  • Integrated heating: Helps manage battery temperature for supported charging operations in colder conditions.
  • LiFePO₄ chemistry: Designed for reliable stationary energy storage.
  • Advanced BMS: Monitors battery operating conditions and provides protective controls.
  • High-current performance: Supports demanding loads within manufacturer-specified limits.
  • Rackmount design: Provides organized installation options for compatible battery racks and enclosures.
  • Modular expansion: Supports compatible multi-battery configurations.
  • LYNK port connectivity: Supports integration with approved inverter systems through compatible communication equipment.
  • Integrated circuit protection: Includes battery-side electrical protection.
  • High round-trip efficiency: Designed to minimize energy losses during charging and discharging.
  • Manufacturer warranty: Supported by Discover Energy's published battery warranty and performance terms.

Integrated Heating for Cold-Weather Battery Performance

Lithium batteries can have charging restrictions at low temperatures. The Discover AES RACKMOUNT heated model includes an integrated heating system designed to help bring the battery into an appropriate charging temperature range.

This feature can be particularly useful for protected installation spaces that experience seasonal temperature changes.

Heated Battery Benefits

  • Supports battery charging readiness during colder conditions.
  • Helps maintain appropriate battery operating temperatures.
  • Works alongside the integrated BMS to manage charging conditions.
  • Provides additional flexibility when planning a protected battery installation.
  • Reduces reliance on ambient room heating alone.

Installation note: Integrated heating does not make the battery weatherproof. The battery must still be installed in a protected location that meets manufacturer environmental requirements.


Advanced Battery Management and LYNK Communication

Discover's AES RACKMOUNT battery includes an intelligent battery management system designed to monitor battery conditions, protect the cells, and support appropriate charging and discharging behavior.

The battery includes a LYNK communication port for connection to compatible external communication equipment.

Discover's optional LYNK II Gateway enables advanced integration with supported hybrid inverter-chargers, including selected Sol-Ark models.

Battery Management Benefits

  • Battery state-of-charge monitoring.
  • Temperature monitoring.
  • Charge and discharge protection.
  • Cell balancing.
  • Compatible inverter communication.
  • Supported diagnostics and battery monitoring.
  • Dynamic charging control with approved integration equipment.

Compatibility note: The LYNK II Gateway is sold separately. The exact Sol-Ark inverter model and supported communication configuration must be verified before installation.


Expandable Energy Storage

The Discover AES RACKMOUNT platform is designed to support modular battery storage expansion.

Compatible battery modules can be combined using approved racks, battery combiners, and communication equipment.

This modular approach allows homeowners to plan for additional storage capacity as their energy requirements change.

Expansion must follow Discover's approved installation guidelines, including electrical protection, battery matching, communication, and enclosure requirements.


Solar Self-Consumption and Energy Storage

This equipment package is designed around generating electricity from solar panels and storing available energy for later use.

When properly configured, a hybrid solar and battery system can help homeowners use more of their solar generation rather than relying exclusively on real-time sunlight.

Potential System Benefits

  • Generate electricity from residential solar panels.
  • Store available solar energy for later consumption.
  • Reduce reliance on utility electricity during supported operating periods.
  • Monitor solar generation and inverter operation.
  • Plan for future battery storage expansion.
  • Support selected backup loads with an approved system configuration.

Actual performance, electricity savings, and backup capability depend on system design, local utility rates, solar production, and household energy consumption.


Ideal Applications

  • Residential off grid solar system projects.
  • Small off grid solar installations for selected electrical loads.
  • Residential solar and battery storage projects.
  • Home solar self-consumption systems.
  • Battery storage in protected locations with seasonal temperature variation.
  • Professionally designed essential-load backup applications.
  • Solar installations with future battery expansion plans.
  • Residential energy management projects.

Product Specifications

Specification Details
SOLAR KIT OVERVIEW
Kit Type Residential Solar and Battery Storage Equipment Kit
Total Solar Array Capacity 3,600W / 3.6kW DC (STC)
Total Nominal Battery Capacity 5.12kWh
Solar Panel Quantity 8
Inverter Quantity 1
Battery Quantity 1
PHILADELPHIA SOLAR PANEL SPECIFICATIONS
Manufacturer Philadelphia Solar
Model / MPN PS-MNB108(HCBF)-450W
Rated Power 450W per Panel
Cell Technology N-Type Monocrystalline, Half-Cell, Bifacial
Module Efficiency Approximately 23.0%
Maximum Power Voltage (Vmp) 33.51V
Maximum Power Current (Imp) 13.44A
Open Circuit Voltage (Voc) 38.84V
Short Circuit Current (Isc) 14.47A
Maximum System Voltage 1,500V DC
Maximum Series Fuse 30A
Module Dimensions Approximately 1,721 × 1,133 × 30mm
Module Weight Approximately 20.5kg
Product Warranty 25 Years
Linear Power Warranty 30 Years
SOL-ARK HYBRID INVERTER SPECIFICATIONS
Manufacturer Sol-Ark
Model / MPN 5K-1P-N
Inverter Type Single-Phase Hybrid Solar Inverter
Maximum Continuous AC Output 4,800W
Nominal AC Output Voltage 120V Single Phase
Maximum AC Output Current 40A
Maximum PV Input Power 10,400W STC
Maximum PV Input Voltage 500V DC
Nominal PV Voltage Range 150–425V DC
PV Startup Voltage 125V DC
MPPT Trackers 2
Maximum PV Input Current per MPPT 26A; Self-Limiting at 20A
Maximum Inverter Efficiency 97.6%
Nominal Battery Voltage 48V DC
Battery Operating Voltage Range 40–60V DC
Maximum Battery Charge/Discharge Current 120A
Communication CANBus, RS485, Wi-Fi, LAN
Enclosure Rating IP65 / NEMA 3R
Standard Warranty 10 Years
DISCOVER ENERGY BATTERY SPECIFICATIONS
Manufacturer Discover Energy Systems
Series AES RACKMOUNT
Model / MPN 48-48-5120-H
Battery Type Heated Rackmount Lithium Battery
Battery Chemistry Lithium Iron Phosphate (LiFePO₄)
Nominal Voltage 51.2V DC
Nominal Energy 5.12kWh
Rated Capacity (1 Hour) 100Ah
Usable Depth of Discharge 100%
Maximum Current (1 Hour) 95A
BMS Peak Discharge 218A RMS for 3 Seconds
Integrated Breaker Dual 100A, 2-Pole Ganged
Battery Terminals Amphenol SurLok Plus
Discharge Temperature Range -17°C to 52°C
Charge Temperature Range 4°C to 52°C
Integrated Heating Range -17°C to 8°C
Battery Form Factor 19-Inch Rack Mount, 3U
Dimensions (L × W × H) 497 × 439 × 133.5mm / 19.6 × 17.3 × 5.3in
Weight 44kg / 97lb
Enclosure Rating IP20
Communication LYNK Port Connectivity
Optional Communication Gateway Discover LYNK II Gateway, MPN 950-0025
Round-Trip Efficiency Up to 98%, Manufacturer-Claimed
Battery Warranty 10 Years, Subject to Manufacturer Terms
Regulatory Standards UN 38.3 DOT, IEC 62619, UL 1973, UL 9540A, UL 9540 — Marked Pending in Supplied Datasheet
SYSTEM COMPATIBILITY
Inverter/Battery Voltage Compatibility Published Voltage Ranges Overlap
Closed-Loop Battery Communication Exact 5K-1P-N Compatibility Requires Confirmation
Optional LYNK II Gateway Not Included
Complete System UL 9540 Listing Not Established for This Exact Combination
Battery Charge/Discharge Settings Must Respect Discover Battery Current Limits
PV String Configuration Installer-Designed Within Inverter Limits

System Compatibility and Installation Requirements

This package combines equipment intended for residential solar generation, hybrid power conversion, and rechargeable battery storage.

Discover's AES RACKMOUNT battery platform supports integration with selected Sol-Ark hybrid inverter-chargers using the appropriate communication equipment. The exact inverter model supplied in this kit must be confirmed as supported before installation.

The battery's current limits, heating requirements, and communication configuration must be considered during system design.

Before Installation

  • Confirm the exact inverter and battery pairing is supported.
  • Verify whether the Discover LYNK II Gateway is required.
  • Confirm supported firmware and battery communication settings.
  • Verify the complete energy storage system's applicable certification.
  • Configure inverter charging and discharging settings within battery limits.
  • Design the photovoltaic string configuration for local environmental conditions.
  • Confirm inverter AC output suitability for intended household loads.
  • Provide compatible battery power cables and mating connectors.
  • Select appropriately rated fuses, breakers, and disconnects.
  • Provide compatible solar mounting and rapid shutdown equipment.
  • Install the battery in a protected environment.
  • Follow applicable electrical codes and utility interconnection requirements.

Additional Equipment Required

This package includes the solar panels, hybrid inverter, and battery identified in the kit contents. The following are not included unless expressly specified:

  • Solar panel mounting and racking hardware.
  • PV extension cables and field wiring.
  • Battery power cables and compatible mating connectors.
  • Battery rack, enclosure, or stacking brackets.
  • Discover LYNK II communication gateway.
  • Required disconnects, breakers, and overcurrent protection.
  • Rapid shutdown equipment where applicable.
  • Electrical distribution and transfer equipment.
  • Installation labor, engineering, and permitting.

Frequently Asked Questions

What is included in this off grid solar kit?

The kit includes eight Philadelphia Solar bifacial panels, one Sol-Ark hybrid inverter, and one Discover Energy AES RACKMOUNT heated lithium battery. Mounting, wiring, communication equipment, and installation accessories are sold separately.

Can this kit be used as an off grid solar system?

The equipment is intended for solar generation and battery storage applications. Off grid operation depends on confirming compatibility between the Sol-Ark inverter and Discover battery, as well as completing the required electrical system design.

Can an off grid solar system power a house?

Yes, a properly sized off grid solar system can supply residential electricity. This particular kit must be evaluated against household energy consumption, peak loads, and seasonal solar production to determine which loads it can support.

How much battery storage do I need for an off grid solar system?

Battery storage requirements depend on daily electricity consumption, overnight loads, expected periods without sunlight, and desired backup duration. Additional batteries may be required for full-time off grid living.

Can this off grid solar kit operate without utility electricity?

Potentially, when installed with an approved inverter-battery configuration and all necessary electrical equipment. The exact system must be verified before it is represented as capable of independent operation.

Is this a complete ready-to-install solar system?

No. The kit includes the major solar generation, inverter, and battery components. Mounting, wiring, electrical protection, and communication accessories must be selected separately.

What is the benefit of a heated lithium battery?

The integrated heating system helps bring the battery into an appropriate charging temperature range during colder conditions.

Can the Discover battery be installed outdoors?

The battery module is not weatherproof. It must be installed in a suitable protected environment or approved enclosure.

Does the Discover battery include a BMS?

Yes. It includes an advanced battery management system that monitors and protects battery operation.

Is the Discover battery compatible with Sol-Ark inverters?

Discover provides integration support for selected Sol-Ark inverter models. The exact inverter supplied in this kit must be confirmed as compatible before installation.

Does the battery require a LYNK II Gateway?

Advanced closed-loop communication with supported inverters may require the Discover LYNK II Gateway. The appropriate configuration must be confirmed for the inverter.

Is the LYNK II Gateway included?

No. The gateway is not included in the listed kit components.

Can additional Discover batteries be added later?

The AES RACKMOUNT platform supports compatible multi-battery configurations using approved connection, protection, and communication equipment.

Are the Philadelphia Solar panels bifacial?

Yes. They can generate electricity from sunlight reaching the front surface and reflected light reaching the rear surface.

Can the solar panels be roof mounted?

Yes. They can be installed using compatible rooftop mounting systems and approved module mounting methods.

Can the panels be ground mounted?

Yes. Ground mounting is possible with suitable structural support and an approved installation design.

Can the system store solar electricity for nighttime use?

That is an intended application of the equipment. Actual operation requires confirmation of inverter-battery compatibility and appropriate settings.

Can this kit provide backup power during an outage?

Potentially, when configured as an approved backup system with suitable electrical equipment and confirmed battery compatibility. Backup capability is not guaranteed by the components alone.

Can this kit power an entire house?

It is better evaluated for selected residential loads. Whole-home suitability depends on electrical service configuration, connected loads, and system design.

Does the kit include solar mounting hardware?

No. Solar mounting and racking hardware are selected separately for the installation.

Does the kit include battery cables?

No. Compatible battery cables and mating connectors must be selected separately unless specifically added to the package.

Is the Discover battery UL 9540A certified?

The supplied manufacturer datasheet identifies UL 9540A among regulatory standards marked pending. Current test documentation and the complete system's certification status should be verified with Discover.

Can I monitor the system remotely?

The Sol-Ark inverter supports network monitoring. Battery monitoring and integration depend on the approved communication configuration and required accessories.

Is professional installation recommended?

Yes. Professional system design and installation are recommended to ensure electrical compatibility, safe operation, and compliance with applicable codes.