Sale

12 Panel Residential Sinclair Sky Rack 2.0 Ground Mount Panel Racking Solar Kit (Seasonal Adjust) Made in USA - 67.7 x 44.6" Panel Size

12 Panel Residential Sinclair Sky Rack 2.0 Ground Mount Panel Racking Solar Kit (Seasonal Adjust) Made in USA - 67.7 x 44.6" Panel Size

Regular price $2,223.00 -5% $2,099
6% OFF
LESS THAN 50
Leave a Review

Sinclair

Freight Sale

12 Panel Residential Sinclair Sky Rack 2.0 Ground Mount Panel Racking Solar Kit (Seasonal Adjust) Made in USA - 67.7 x 44.6" Panel Size

12 Panel Residential Sinclair Sky Rack 2.0 Ground Mount Panel Racking Solar Kit (Seasonal Adjust) Made in USA - 67.7 x 44.6" Panel Size

Available
MPN No: Sky Rack 2.0 Solar Kit - 12 Panel (Residential)
Regular price $2,223.00 -5% $2,099

1
2
3
4
5

Shipping calculated at checkout. About shipping

Installation Manual: Sky Rack 2.0
Data sheet: Sinclair Sky Rack 2.0 Ground Mount
Panel Sizing Guide (SM)

U.S. Warehouse

Trusted by Thousands

Expert U.S. Support

View full details
Regular price $2,223.00 -5% $2,099
Made in USA

12-Panel Sinclair Sky-Rack 2.0 Ground Mount Kit

Seasonally adjustable galvanized-steel racking for residential-size solar modules measuring approximately 67.75 × 44.60 inches

Solar panels are not included.

This package gives homeowners and installers a permanent ground-mount structure for a 12-panel solar array without placing panels on the roof. The Sky-Rack 2.0 uses galvanized-steel posts, trusses, support struts and Z-purlins, with manual seasonal adjustment from 15° to 60°.

A site-specific plan package without an engineering stamp is included. After purchase, US Solar Supplier will send a project form to collect the site and module information needed to prepare the final configuration.

12 Panels Residential-size module configuration
15°–60° Manual seasonal adjustment range
UL 2703 Evaluated bonding and grounding system
25 Years Manufacturer warranty

Is This the Right Ground Mount for Your Project?

A Good Fit If You Want

  • A permanent 12-panel array installed away from the roof
  • Seasonal tilt adjustment for changing sun angles and winter conditions
  • Galvanized-steel construction and a 25-year manufacturer warranty
  • A project-specific rack configuration and unstamped plan package
  • A low-sloped site with room for foundation work and service access

Confirm Another Mounting Style If You Need

  • A portable or temporary array
  • A no-dig or fully ballasted installation
  • A rack that can be installed without pile-driving, excavation or concrete work
  • A fixed low-profile frame for steep, highly uneven or obstructed ground
  • Parcel-size shipping or liftgate delivery

What’s Included

Included in This Package

  • Sinclair Sky-Rack 2.0 structural package configured for 12 panels
  • C-channel posts, trusses, support struts and Z-purlins
  • Seasonal-adjust jacks and rack assembly hardware for the selected configuration
  • Module attachment and bonding components shown on the final bill of materials
  • Site-specific plan package without an engineering stamp

Not Included

  • Solar panels, inverter, wiring, conduit and other electrical equipment
  • Installation labor, concrete, excavation or pile-driving equipment
  • Stamped engineering unless purchased separately
  • Forklift, crane, unloading crew or job-site placement
  • Poly U Guard wire-management kit

View the optional Poly U Guard Wire Management Kit for 12-panel Sinclair arrays.


How the Project Moves Forward

1

Order the Rack

Place the order for the 12-panel seasonal-adjust configuration.

2

Complete the Project Form

Provide the site address, panel model, frame dimensions and requested project details.

3

Confirm the Design

The rack configuration and unstamped site-specific plan are prepared. Required stamped engineering is handled separately.

4

Schedule Delivery

Oversized components are shipped through the enhanced delivery process described below.


Specialized Final-Mile Delivery

This rack requires specialized freight because the long, heavy galvanized-steel components cannot move through a normal parcel network. The delivery plan is designed to reduce unnecessary handling and bring the shipment to the destination using equipment better suited to oversized racking.

Destinations Under 1,000 Miles

The order is scheduled on a dedicated 26-foot enclosed box truck from the shipping warehouse to the destination, with pickup photos and driver assistance at delivery.

Destinations Over 1,000 Miles

The shipment travels by LTL linehaul to a terminal near the destination, then transfers to a box truck for final-mile delivery with driver assistance.

An adult customer or installation representative must be present and prepared to help hand-unload the racking. Delivery does not include an unloading crew, forklift, crane, installation, assembly or placement around the property. Confirm that the address has safe access and turning room for a 26-foot box truck before ordering.

Shipping is based on the service required for oversized racking, not mileage alone. If you are near an available pickup location, contact US Solar Supplier before ordering to ask whether pickup or another approved delivery option is available for your order.


Designed for These Panel Dimensions

This configuration is intended for residential-size solar modules within the following dimensional tolerances:

Panel Length

67.75 inches ± 1.5 inches

Panel Width

44.60 inches ± 1.0 inch

Dimensions are only the first compatibility check. Send the exact panel manufacturer, model number, frame specifications and maximum series-fuse rating before the order is released. Sinclair’s current installation manual specifies modules with a maximum series-fuse rating of 20A and has different bonding requirements for direct-bolted and clamp-mounted modules.

Examples of residential-size solar modules for the Sinclair Sky-Rack configuration

Site Planning, Permits and Engineering

Included Plan Package

A site-specific plan package without an engineering stamp is included. A project-information form will be sent after purchase.

Stamped Engineering

Your authority having jurisdiction may require stamped structural documents. State-specific engineering can be arranged for an additional fee.

Standard Structural Configuration

The standard US Solar Supplier package is offered for site requirements up to 125 mph wind and 60 psf snow, subject to the final site-specific design, foundation conditions and local approval.

Higher Design Requirements

Additional structural features may be available for sites that exceed the standard wind or snow requirements. Contact US Solar Supplier before ordering.

Ground-mounted arrays may be regulated as accessory structures. Before installation, confirm zoning, setbacks, maximum height, easements, permit requirements, electrical requirements and whether a professional engineer’s stamp is required. Local rules vary by city, county and state.

Sinclair site-specific project form notice

Foundation and Installation Expectations

This is a structural ground-mount system, not a tool-free backyard frame. Foundation type and depth depend on soil, frost depth, terrain, wind, snow and the final design. Sinclair’s manual describes driven C-channel posts, concrete footers and concrete ballast as possible approaches, but the final method must be selected for the project.

Site Conditions to Check

  • Low-sloped, stable terrain with suitable solar exposure
  • Soil strength, frost depth, bedrock, roots and drainage
  • Property setbacks, easements, septic areas and buried utilities
  • Access for installation equipment and future mowing or service

Common Installation Equipment

  • Pile-driving or excavation equipment selected for the foundation design
  • Self-leveling laser, receiver, levels, mason’s line and tape measure
  • Impact driver, sockets, spanners and adjustable torque wrench
  • Approved anti-seize and required personal protective equipment

Call 811 a few business days before any digging or pile driving and wait for underground utilities to be marked. Installation should follow the final Sinclair drawing package, the current installation manual, applicable electrical and building codes, and local inspection requirements.


Seasonal Tilt Adjustment

The seasonal-adjust configuration allows the array angle to be changed manually from 15° to 60°. A steeper winter setting can improve alignment with a lower sun angle and may help shed snow. A lower summer setting can better match higher seasonal sun angles. Actual production depends on the site, climate, shading, orientation and adjustment schedule.

Sinclair instructs installers to adjust the jack at each post in 5-degree increments to avoid damaging the array. Seasonal changes should be completed by people who understand the rack, can control the structure safely and can verify the required hardware position afterward.


Wire Management and Long-Term Care

Ground-mounted wiring is exposed to movement, sunlight, vegetation work and wildlife. Keep conductors supported away from sharp edges, moving parts and the ground, and inspect the array periodically for loose hardware, cable abrasion, corrosion, vegetation growth and animal damage.

The optional Poly U Guard kit provides a cleaner protected pathway beneath the array using Poly U Guard sections, stainless clips and mounting hardware. It is sold separately and is especially worth considering where mowing, rodents or exposed cable runs are concerns.

Add the Poly U Guard Wire Management Kit.


What to Confirm Before Ordering

  • Exact solar-panel manufacturer, model, frame dimensions and maximum series-fuse rating
  • Project address, design wind speed, ground snow load and permitting authority
  • Required setbacks, height restrictions, easements and HOA rules
  • Soil, frost, slope, drainage, root and bedrock conditions
  • Foundation method and access to the required installation equipment
  • Whether stamped structural engineering is required
  • Safe access and turning room for a 26-foot box truck
  • Enough people or suitable equipment to unload the steel safely

Need help confirming panel fit, engineering requirements or delivery access? Call 1-800-230-7004 or email sales@ussolarsupplier.com before placing the order.


Product Specifications

Specification Details
Manufacturer Sinclair Designs & Engineering
Product Sky-Rack 2.0 Ground Mount System
Configuration 12 residential-size solar panels
Compatible Panel Length 67.75 in ± 1.5 in
Compatible Panel Width 44.60 in ± 1.0 in
Module Series-Fuse Rating 20A maximum per current Sinclair installation manual
Mount Type Permanent ground mount for low-sloped terrain
Fixed-Tilt Range 5°–35°
Seasonal-Adjust Range 15°–60°, manually adjusted
Primary Material Galvanized steel
Certification UL 2703 evaluated bonding and grounding system
Standard Site Requirement Up to 125 mph wind and 60 psf snow, subject to final site-specific design and local approval
Site-Specific Plans Included without engineering stamp
Stamped Engineering Available for an additional fee when required
Solar Panels Not included
Wire Management Optional Poly U Guard kit sold separately
Shipping Method Specialized freight with final-mile delivery; applicable charge shown at checkout
Unloading Driver assist with customer or installer prepared to hand-unload; unloading equipment not included
Country of Manufacture USA
Warranty 25-year manufacturer warranty
ManufacturerSinclair Designs & Engineering
ProductSky-Rack 2.0 Ground Mount System
Configuration12 residential-size solar panels
Panel Dimensions67.75 in ± 1.5 in long · 44.60 in ± 1.0 in wide
Module Series-Fuse Rating20A maximum per current Sinclair installation manual
Tilt RangeFixed: 5°–35° · Seasonal: 15°–60°
MaterialGalvanized steel
CertificationUL 2703 evaluated bonding and grounding system
Standard Site RequirementUp to 125 mph wind and 60 psf snow, subject to final site-specific design and local approval
PlansSite-specific plan package included without stamp; stamped engineering available for an additional fee
Solar PanelsNot included
ShippingSpecialized freight with final-mile delivery; applicable charge shown at checkout
UnloadingDriver assist with customer or installer prepared to hand-unload; unloading equipment not included
Warranty25-year manufacturer warranty

Final component quantities, attachment method, foundation requirements and structural details are controlled by the approved project configuration. Installation must comply with the final Sinclair drawing package, the current installation manual and all applicable local requirements.


Frequently Asked Questions

Why is shipping so high for this rack?

The rack includes long, heavy galvanized-steel components that cannot move through a normal parcel network. Shipping reflects the truck type, oversized-item handling, freight transfers, destination access and final-mile coordination required to deliver the rack safely. Distance is only one part of the cost, which is why a nearby destination may not price like a normal local parcel delivery. If you are near an available pickup location, contact us before ordering to see whether pickup or another approved option is available.

What happens when the rack is delivered?

The driver brings the shipment to the delivery address and assists with hand unloading. An adult customer or installation representative must be present with enough help or suitable equipment to unload the long steel components safely. Inspect the shipment, note visible damage on the delivery paperwork and take photos before the driver leaves.

Is this white-glove delivery?

No. This is enhanced final-mile freight with driver assistance, not inside delivery or installation. It does not include an unloading crew, forklift, crane, assembly, job-site placement or movement around the property.

Are solar panels included?

No. This listing includes the Sinclair ground-mount racking package and the associated unstamped site-specific plan package. Solar panels and electrical equipment are sold separately.

Will my panels fit this rack?

This configuration is intended for modules approximately 67.75 inches long and 44.60 inches wide within the listed tolerances. Fit also depends on the panel frame, attachment method and documentation. Send the exact manufacturer and model before ordering so compatibility can be confirmed.

Why does the panel’s series-fuse rating matter?

Sinclair’s current Sky-Rack 2.0 installation manual specifies modules with a maximum series-fuse rating of 20A. Many newer modules have higher ratings, so the panel data sheet must be checked before the rack configuration is finalized.

Are stamped engineering documents included?

No. The included site-specific plan package is not stamped. If your state or local permitting authority requires a professional engineer’s stamp, that service can be arranged for an additional fee.

Do I need a permit for a residential ground mount?

Requirements vary. Ground-mounted solar may be reviewed as an accessory structure and can be subject to zoning, setback, height, structural and electrical rules. Contact the local building and zoning offices before installation and confirm whether stamped plans are required.

How deep do the posts or footings need to be?

There is no universal depth. Sinclair’s manual gives average examples, including driven-post embedment of approximately 6.5 to 8.5 feet and 24-inch-diameter concrete footers approximately 6 to 7 feet deep, but the actual requirement depends on the final engineering, soil, frost depth, terrain and local loads.

What if the site has rock, roots, steep slope or poor drainage?

Pause before ordering and review the site with the installer or engineer. Obstructions and difficult soil can change the foundation method, equipment, location or project cost. The Sky-Rack is intended for low-sloped terrain, and the foundation must be selected for the actual site.

Can I install this without heavy equipment?

The rack assembly uses common layout and fastening tools, but the foundation normally requires suitable pile-driving, excavation, concrete or ballast equipment. Those tools, machines, materials and installation labor are not included.

Can I adjust the tilt by myself?

Seasonal adjustment is manual and must be controlled safely at every post. Sinclair instructs users to change each jack in 5-degree increments to avoid damaging the array. Use qualified help when needed and follow the current manual and project drawing.

Does seasonal adjustment guarantee more production?

No fixed increase is guaranteed. Adjustment can improve seasonal alignment and a steeper winter angle may help shed snow, but results depend on location, orientation, shade, weather and how consistently the array is adjusted.

What if my site exceeds 125 mph wind or 60 psf snow?

Contact US Solar Supplier before ordering. Additional structural features and engineering may be available for sites with higher design requirements.

Is the Poly U Guard wire-management kit included?

No. It is an optional add-on sold separately. It creates a protected pathway beneath the array and can help keep wiring organized and away from abrasion, vegetation work and animal exposure.


About Sinclair Designs & Engineering

Sinclair Designs & Engineering is a veteran- and family-owned American manufacturer established in 2007. The Sky-Rack 2.0 combines galvanized-steel construction, project-specific configuration, seasonal adjustment and a UL 2703 evaluated bonding and grounding system.


Why Buy From US Solar Supplier

US Solar Supplier is an American-founded company based in Kentucky. Our team can help confirm module compatibility, site-planning requirements, optional engineering and delivery access before the order is released.

Call 1-800-230-7004 or email sales@ussolarsupplier.com for help with this Sinclair ground-mount package.