{"product_id":"victron-energy-lynx-smart-bms-1000-m10-lyn034170210","title":"Victron Energy Lynx Smart BMS 1000A (M10) Battery Management System – LYN034170210","description":"\u003ch2\u003e\u003cstrong\u003eVictron Energy Lynx Smart BMS 1000A (M10) Battery Management System – LYN034170210\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Victron Energy LYN034170210 Lynx Smart BMS 1000A (M10) is a high-current battery management system designed specifically for Victron Lithium Battery Smart LiFePO₄ batteries.\u003c\/p\u003e\n\u003cp\u003eIt combines a 1000A main safety contactor, integrated pre-charge circuit, built-in battery monitoring, Bluetooth connectivity, VE.Can communication, DVCC control, programmable relay functionality, and Lynx Distributor fuse monitoring in a single M10-compatible module. \u003c\/p\u003e\n\u003cp\u003eDesigned for compatible 12V, 24V, and 48V battery systems, the Lynx Smart BMS integrates directly into the Victron Lynx Distribution System and supports up to 20 Lithium Battery Smart batteries in one BMS system.\u003c\/p\u003e\n\u003cp\u003eIt can be monitored and controlled through VictronConnect or a compatible GX device, while multiple Lynx Smart BMS units can be used in supported parallel redundant system architectures. \u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technology\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1000A Main Safety Contactor\u003c\/strong\u003e\u003cbr\u003eThe integrated high-current contactor acts as a secondary battery-protection system if primary ATC, ATD, or DVCC controls fail to disable charging equipment or loads when required. It can also function as a remotely controllable main system switch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-In Pre-Charge Circuit\u003c\/strong\u003e\u003cbr\u003eLimits high inrush current when connecting compatible capacitive loads such as inverter\/chargers and other inverters, eliminating the need for a separate external pre-charge device in supported installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Battery Monitor\u003c\/strong\u003e\u003cbr\u003eProvides real-time battery information including state of charge, voltage, current, historical data, operating status, and other battery-monitoring information.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-In Bluetooth\u003c\/strong\u003e\u003cbr\u003eEnables local monitoring and control through the VictronConnect app, including Instant Readout for convenient system diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVE.Can \u0026amp; GX Integration\u003c\/strong\u003e\u003cbr\u003eProvides VE.Can communication for connection to compatible Victron GX equipment, enabling centralized system monitoring and integration with the VRM platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDVCC Closed-Loop Control\u003c\/strong\u003e\u003cbr\u003eCompatible Victron inverter\/chargers and solar charge controllers can be automatically controlled through a connected GX device using DVCC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eATC \u0026amp; ATD Control\u003c\/strong\u003e\u003cbr\u003eAllow-to-Charge and Allow-to-Discharge contacts can control compatible chargers and loads equipped with appropriate remote on\/off inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammable Relay\u003c\/strong\u003e\u003cbr\u003eThe integrated relay can operate as an alarm relay with the pre-alarm function or control an alternator through an external regulator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLynx Distributor Fuse Monitoring\u003c\/strong\u003e\u003cbr\u003eMonitors fuse status for up to four connected Lynx Distributor modules and provides fuse-failure information through VictronConnect or compatible GX equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eParallel Redundant BMS Support\u003c\/strong\u003e\u003cbr\u003eMultiple Lynx Smart BMS units can operate in supported parallel configurations, with each BMS managing its own battery bank to create a redundant battery system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eBest Uses\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVictron Lithium Battery Smart Systems\u003c\/strong\u003e\u003cbr\u003eDesigned specifically for compatible Victron Lithium Battery Smart LiFePO₄ battery banks requiring centralized protection and monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Battery Systems\u003c\/strong\u003e\u003cbr\u003eSuitable for properly engineered battery systems requiring substantial continuous DC current capability and integrated battery protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVictron Lynx Distribution Systems\u003c\/strong\u003e\u003cbr\u003eDesigned to integrate with compatible Lynx modules for organized high-current DC distribution, protection, and system monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGX-Integrated Energy Systems\u003c\/strong\u003e\u003cbr\u003eIdeal for systems using compatible GX devices for centralized monitoring, DVCC control, and remote system information.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInverter\/Charger \u0026amp; Solar Systems\u003c\/strong\u003e\u003cbr\u003eSupports coordinated control of compatible Victron inverter\/chargers and solar charge controllers through GX and DVCC integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Battery Architectures\u003c\/strong\u003e\u003cbr\u003eSuitable for supported installations where multiple independently managed battery banks are combined to provide battery-system redundancy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eVictron Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eLynx Smart BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLynx Smart BMS 1000A (M10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd\u003eLYN034170210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBattery Management System \/ Battery Monitor \/ Main Safety Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Battery Family\u003c\/td\u003e\n\u003ctd\u003eVictron Lithium Battery Smart (LiFePO₄)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range\u003c\/td\u003e\n\u003ctd\u003e9–60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd\u003e75V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported System Voltages\u003c\/td\u003e\n\u003ctd\u003e12V, 24V, or 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Safety Contactor Continuous Rating\u003c\/td\u003e\n\u003ctd\u003e1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Safety Contactor Peak Rating\u003c\/td\u003e\n\u003ctd\u003e1200A for 5 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption – OFF Mode\u003c\/td\u003e\n\u003ctd\u003e0.3mA for All System Voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption – Standby Mode\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.6W (50mA at 12V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption – ON Mode\u003c\/td\u003e\n\u003ctd\u003eApproximately 4.2W (350mA at 12V), Depending on Relay State\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Resistance for Pre-Charging – 12V\u003c\/td\u003e\n\u003ctd\u003e10Ω and Above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Resistance for Pre-Charging – 24V \/ 48V\u003c\/td\u003e\n\u003ctd\u003e20Ω and Above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAUX Output Maximum Current\u003c\/td\u003e\n\u003ctd\u003e1.1A Continuous, Protected by Resettable Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllow-to-Charge Port Maximum Rating\u003c\/td\u003e\n\u003ctd\u003e0.5A at 60V DC, Protected by Resettable Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllow-to-Discharge Port Maximum Rating\u003c\/td\u003e\n\u003ctd\u003e0.5A at 60V DC, Protected by Resettable Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay\u003c\/td\u003e\n\u003ctd\u003eSPDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Maximum Rating\u003c\/td\u003e\n\u003ctd\u003e2A at 60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBusbar Connection\u003c\/td\u003e\n\u003ctd\u003eM10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBusbar Torque\u003c\/td\u003e\n\u003ctd\u003e33 Nm; 17 Nm for Units with Serial Number Before HQ2340XXXX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVE.Can Connection\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Connection\u003c\/td\u003e\n\u003ctd\u003eRemovable Multi-Connector with Screw Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery BTV Connections\u003c\/td\u003e\n\u003ctd\u003eMale and Female Circular 3-Pole Connector with M8 Screw Ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Batteries per BMS System\u003c\/td\u003e\n\u003ctd\u003eUp to 20 Compatible Lithium Battery Smart Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLynx Distributor Fuse Monitoring\u003c\/td\u003e\n\u003ctd\u003eUp to 4 Modules via RJ10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Parallel BMS Units\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBusbar Material\u003c\/td\u003e\n\u003ctd\u003eTinned Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Dimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e9.06 × 7.09 × 3.94 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBusbar Dimensions (H × W)\u003c\/td\u003e\n\u003ctd\u003e0.31 × 1.18 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e5.95 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C (-40°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C (-40°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Humidity\u003c\/td\u003e\n\u003ctd\u003e95%, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eEN-IEC 63000:2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standard\u003c\/td\u003e\n\u003ctd\u003eEN-IEC 61000-6-3:2007\/A1:2011\/AC:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality Management Standard\u003c\/td\u003e\n\u003ctd\u003eNEN-EN-ISO 9001:2015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAbout Victron Energy:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eVictron Energy develops power-conversion, battery-management, charging, monitoring, and DC distribution equipment for battery-based electrical systems. Its portfolio includes inverter\/chargers, battery chargers, DC-DC converters and chargers, solar charge controllers, batteries, battery management equipment, GX monitoring devices, communications products, and system accessories.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eHigh-Current Battery Management for Victron Lithium Smart Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Victron Energy LYN034170210 Lynx Smart BMS 1000A (M10) combines high-current battery protection, a 1000A integrated safety contactor, pre-charge circuitry, precision battery monitoring, Bluetooth, VE.Can, DVCC control, programmable system interfaces, Lynx Distributor fuse monitoring, and redundant BMS capability. It provides a centralized battery-management solution for compatible Victron Lithium Battery Smart systems requiring substantial DC current capacity and integration with the Lynx Distribution System.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Buy From US Solar Supplier\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUS Solar Supplier is an American-founded company based in Kentucky dedicated to offering top-quality solar components from trusted manufacturers. We provide competitive pricing, dependable inventory, and products backed by warranties you can trust.\u003c\/p\u003e\n\u003cp\u003eOur inventory is updated daily with the latest solar technologies, and our experienced team is ready to assist with product selection, system design, and installation guidance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eNeed Assistance?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eHave questions before you order? Call \u003cstrong\u003e1-800-230-7004\u003c\/strong\u003e to speak with our knowledgeable support team. We’re here to help with product details, compatibility questions, or purchasing support.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52561797021994,"sku":"USSSP202-1310","price":1178.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/3408\/1340\/files\/LYN034170210_USSS.jpg?v=1790615369","url":"https:\/\/ussolarsupplier.com\/products\/victron-energy-lynx-smart-bms-1000-m10-lyn034170210","provider":"US Solar Supplier","version":"1.0","type":"link"}