{"product_id":"victron-energy-inverter-48-1200-120v-ve-direct-nema-5-15r-pin482122520","title":"Victron Energy Inverter 48\/1200 120V VE.Direct NEMA 5-15R - PIN482122520","description":"\u003ch2\u003e\u003cstrong\u003eVictron Energy Inverter 48\/1200 120V VE.Direct NEMA 5-15R - PIN482122520\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cstrong\u003e \u003c\/strong\u003eVictron Energy Phoenix Inverter 48\/1200 120V VE.Direct, manufacturer part number PIN482122520, is a high-performance pure sine wave inverter designed to convert DC electricity from a nominal 48V battery system into reliable 120V AC power. Featuring a 1200VA continuous apparent power rating, high startup capability, VE.Direct communication, and programmable ECO mode, the Phoenix 48\/1200 provides dependable power conversion for off-grid solar installations, residential backup systems, marine applications, mobile electrical systems, and remote power equipment.\u003c\/p\u003e\n\u003cp\u003eBuilt using Victron Energy's proven full-bridge inverter architecture and toroidal transformer technology, the Phoenix 48\/1200 delivers stable pure sine wave electricity suitable for compatible appliances, electronic devices, lighting systems, and other AC equipment. Its robust design is engineered to accommodate electrical loads with demanding startup characteristics while maintaining dependable power conversion under normal operating conditions.\u003c\/p\u003e\n\u003cp\u003eFeaturing a durable steel chassis, blue protective cover, fan-assisted cooling, and screw-terminal battery connections, this inverter is designed for installation in suitable protected electrical environments. Its combination of high startup capability, configurable operation, and dependable AC power conversion makes it an excellent choice for professionally designed 48V battery systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The PIN482122520 is a 48V DC to 120V AC pure sine wave inverter. It is not a battery charger, inverter\/charger, or solar MPPT charge controller. Battery charging and automatic AC source transfer require separate compatible equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technology\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1200VA Continuous Apparent Power:\u003c\/strong\u003e Provides dependable AC power conversion for compatible electrical loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000W Continuous Output at 25°C:\u003c\/strong\u003e Delivers rated real power under the manufacturer's specified operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e850W Continuous Output at 40°C:\u003c\/strong\u003e Maintains useful power capability under elevated ambient temperature conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2200W Peak Power:\u003c\/strong\u003e Supports short-duration startup demands for compatible appliances and equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e48V DC Battery Input:\u003c\/strong\u003e Designed for nominal 48V battery banks and compatible DC power sources.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120V AC Output:\u003c\/strong\u003e Supplies North American AC voltage for compatible electrical equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure Sine Wave Output:\u003c\/strong\u003e Provides clean AC electricity for supported electronic devices and appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVE.Direct Communication:\u003c\/strong\u003e Supports monitoring and configuration through compatible Victron interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable ECO Mode:\u003c\/strong\u003e Helps reduce unnecessary battery consumption when connected loads are low.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-Bridge Inverter Technology:\u003c\/strong\u003e Uses Victron's established power conversion architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eToroidal Transformer Design:\u003c\/strong\u003e Supports reliable operation and high startup power capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable AC Output Frequency:\u003c\/strong\u003e Supports 50Hz or 60Hz operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Low-Battery Protection:\u003c\/strong\u003e Allows configuration of alarm, shutdown, and restart voltage settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Low-Voltage Cut-Off:\u003c\/strong\u003e Supports load-dependent low-battery shutdown behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote On\/Off Control:\u003c\/strong\u003e Enables operation through a compatible external switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Short-Circuit Protection:\u003c\/strong\u003e Incorporates electronic protection against AC output short circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Protection:\u003c\/strong\u003e Helps protect the inverter against excessive electrical demand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Voltage Protection:\u003c\/strong\u003e Includes protection against excessively high or low DC input voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Protection:\u003c\/strong\u003e Protects against overheating due to high load or elevated ambient temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Ripple Protection:\u003c\/strong\u003e Helps protect the inverter against excessive DC input ripple.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan-Assisted Cooling:\u003c\/strong\u003e Supports operation under demanding electrical loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Diagnostics:\u003c\/strong\u003e Provides visual indication of inverter operating conditions and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Bluetooth Connectivity:\u003c\/strong\u003e Supports wireless configuration through a separately purchased VE.Direct Bluetooth Smart dongle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Transfer Switch Compatibility:\u003c\/strong\u003e Can be integrated with a compatible automatic transfer switch such as the Victron Filax.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eBest Uses\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Grid Solar Power Systems:\u003c\/strong\u003e Converts energy stored in compatible 48V battery banks into 120V AC electricity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential Backup Power:\u003c\/strong\u003e Supports selected household loads when integrated into a properly designed backup power system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Cabins:\u003c\/strong\u003e Provides AC electricity for compatible lighting, electronics, and appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecommunications Equipment:\u003c\/strong\u003e Supplies dependable AC power from suitable 48V DC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Electrical Installations:\u003c\/strong\u003e Provides pure sine wave power for compatible onboard electrical equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMobile Power Applications:\u003c\/strong\u003e Supports suitable vehicle and mobile electrical systems using 48V battery storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Monitoring Equipment:\u003c\/strong\u003e Powers compatible electronic controls, communication devices, and monitoring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Workstations:\u003c\/strong\u003e Provides AC electricity for suitable off-grid equipment installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Power Systems:\u003c\/strong\u003e Can supply selected loads when combined with appropriate batteries and external switching equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy-Efficient Standby Applications:\u003c\/strong\u003e Uses ECO mode to reduce power consumption during periods of low demand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eVictron Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003ePhoenix Inverter 48\/1200 120V VE.Direct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd\u003ePIN482122520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePhoenix Inverter VE.Direct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePure Sine Wave DC-to-AC Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Battery Voltage\u003c\/td\u003e\n\u003ctd\u003e48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Output\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Apparent Power Rating\u003c\/td\u003e\n\u003ctd\u003e1200VA at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Input Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e36.8–62.0V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Low-Battery Shutdown Voltage\u003c\/td\u003e\n\u003ctd\u003e37.2V DC, Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Low-Battery Restart and Alarm Voltage\u003c\/td\u003e\n\u003ctd\u003e43.6V DC, Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Battery-Charged Detection Voltage\u003c\/td\u003e\n\u003ctd\u003e56.0V DC, Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Low-Voltage Cut-Off\u003c\/td\u003e\n\u003ctd\u003eProgrammable, Load Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Connection Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC Cable Cross-Section for 48V Model\u003c\/td\u003e\n\u003ctd\u003e25mm² \/ AWG4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC Output Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz or 60Hz, Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Apparent Power at 25°C\u003c\/td\u003e\n\u003ctd\u003e1200VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Real Power at 25°C\u003c\/td\u003e\n\u003ctd\u003e1000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Real Power at 40°C\u003c\/td\u003e\n\u003ctd\u003e850W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Output Power\u003c\/td\u003e\n\u003ctd\u003e2200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Efficiency for 48V Model\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Outlet Options for 120V Series\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15R and GFCI Variants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Outlet Configuration\u003c\/td\u003e\n\u003ctd\u003eConfirm for SKU PIN482122520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePower Consumption and ECO Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Load Power Consumption\u003c\/td\u003e\n\u003ctd\u003e10W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Zero-Load Consumption in ECO Mode\u003c\/td\u003e\n\u003ctd\u003e3.0W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault ECO Mode Retry Interval\u003c\/td\u003e\n\u003ctd\u003e2.5 Seconds, Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECO Mode Load Threshold\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum ECO Mode Load Setting\u003c\/td\u003e\n\u003ctd\u003e15W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCommunication and Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eVE.Direct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBluetooth Connectivity\u003c\/td\u003e\n\u003ctd\u003eAvailable Through Optional VE.Direct Bluetooth Smart Dongle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Connectivity\u003c\/td\u003e\n\u003ctd\u003eAvailable Through Optional VE.Direct-to-USB Interface Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eProgrammable Through Compatible VE.Direct Interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Parameters\u003c\/td\u003e\n\u003ctd\u003eDC Input Voltage, AC Output Voltage, Load Percentage, and Alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote On\/Off\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Control Connection\u003c\/td\u003e\n\u003ctd\u003eTwo-Pole Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Diagnostics\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Transfer Switching\u003c\/td\u003e\n\u003ctd\u003eRequires Separate Compatible Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended External Transfer Switch\u003c\/td\u003e\n\u003ctd\u003eVictron Filax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Battery Voltage Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery Voltage Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvertemperature Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcessive DC Ripple Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +65°C \/ -40°F to +149°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Derating\u003c\/td\u003e\n\u003ctd\u003e1.25% per °C Above 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eFan-Assisted Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e95%, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection Rating\u003c\/td\u003e\n\u003ctd\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Material\u003c\/td\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCover Material\u003c\/td\u003e\n\u003ctd\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCover Color\u003c\/td\u003e\n\u003ctd\u003eBlue, RAL 5012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e4.6 × 9.1 × 12.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e16.3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eStandards and Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN-IEC 60335-1, EN-IEC 62109-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL 458\u003c\/td\u003e\n\u003ctd\u003eApplicable to GFCI Output Socket Versions Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standards\u003c\/td\u003e\n\u003ctd\u003eEN 55014-1, EN 55014-2, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomotive Directive\u003c\/td\u003e\n\u003ctd\u003eECE R10-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003eSubject to Applicable Victron Energy Warranty Terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAbout Victron Energy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eVictron Energy\u003c\/strong\u003e is a globally recognized manufacturer of electrical power conversion, battery charging, energy storage, and monitoring equipment.\u003c\/p\u003e\n\u003cp\u003eIts product portfolio includes inverters, inverter\/chargers, solar charge controllers, DC-DC converters, battery monitors, and integrated system management solutions.\u003c\/p\u003e\n\u003cp\u003eVictron products are widely used in marine, automotive, off-grid, industrial, and renewable energy applications requiring dependable power conversion and flexible system integration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eReliable 48V-to-120V AC Power with Victron Phoenix 48\/1200\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Victron Energy Phoenix Inverter 48\/1200 120V VE.Direct PIN482122520 combines pure sine wave output, high startup power, VE.Direct monitoring, programmable ECO mode, and comprehensive electrical protection in a dependable DC-to-AC inverter.\u003c\/p\u003e\n\u003cp\u003eDesigned for compatible 48V battery systems, the Phoenix 48\/1200 provides an excellent power conversion solution for off-grid solar installations, backup power systems, mobile applications, and remote equipment requiring reliable 120V AC electricity.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Buy From US Solar Supplier\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUS Solar Supplier is an American-founded company based in Kentucky dedicated to offering top-quality solar components from trusted manufacturers. We provide competitive pricing, dependable inventory, and products backed by warranties you can trust.\u003c\/p\u003e\n\u003cp\u003eOur inventory is updated daily with the latest solar technologies, and our experienced team is ready to assist with product selection, system design, and installation guidance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eNeed Assistance?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eHave questions before you order? Call \u003cstrong\u003e1-800-230-7004\u003c\/strong\u003e to speak with our knowledgeable support team. We're here to help with product details, compatibility questions, or purchasing support.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52561798889770,"sku":"USSSP202-1325","price":317.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/3408\/1340\/files\/VictronEnergyInverter48-1200120V.png?v=1793368213","url":"https:\/\/ussolarsupplier.com\/products\/victron-energy-inverter-48-1200-120v-ve-direct-nema-5-15r-pin482122520","provider":"US Solar Supplier","version":"1.0","type":"link"}