{"product_id":"5-4kw-off-grid-solar-kit-with-sol-ark-5k-10-24kwh-discover-batteries","title":"5.4kW Off Grid Solar Kit with Sol-Ark 5K \u0026 10.24kWh Discover Heated Lithium Batteries","description":"\u003cstyle\u003e\n.uss-product{color:#222;font-size:16px;line-height:1.65}\n.uss-product h2{color:#020079;margin:30px 0 12px;line-height:1.3}\n.uss-product h3{color:#020079;margin:22px 0 10px}\n.uss-product ul{padding-left:24px}\n.uss-product li{margin-bottom:8px}\n.uss-product hr{border:0;border-top:1px solid #D9DDE5;margin:28px 0}\n.uss-highlight{background:#F5F7FF;border-left:4px solid #0021F3;padding:16px 20px;margin:18px 0}\n.uss-kit{background:#F5F7FF;border-left:4px solid #0021F3;padding:18px 22px;margin:15px 0 24px}\n.uss-spec-wrap{overflow-x:auto}\n.uss-specs{width:100%;border-collapse:collapse}\n.uss-specs th{background:#020079;color:#fff;padding:12px;text-align:left}\n.uss-specs td{padding:11px 12px;border-bottom:1px solid #D9DDE5;vertical-align:top}\n.uss-specs td:first-child{width:43%;font-weight:600}\n.uss-specs .section td{background:#EEF1FA;color:#020079;font-weight:700}\n.uss-faq details{border:1px solid #D9DDE5;margin-bottom:10px}\n.uss-faq summary{background:#F5F7FF;color:#020079;padding:14px 16px;font-weight:700;cursor:pointer}\n.uss-faq details p{padding:0 16px 14px}\n@media(max-width:640px){\n.uss-product{font-size:15px}\n.uss-specs td,.uss-specs th{padding:9px}\n}\n\u003c\/style\u003e\n\u003carticle class=\"uss-product\"\u003e\n\u003ch2\u003e5.4kW Off Grid Solar Kit with Sol-Ark 5K \u0026amp; 10.24kWh Discover Batteries\u003c\/h2\u003e\n\u003ch3\u003eWhat's Included in the Kit\u003c\/h3\u003e\n\u003cdiv class=\"uss-kit\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 × Philadelphia Solar 450W N-Type Bifacial Solar Panels \u003c\/strong\u003ePS-MNB108(HCBF)-450W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 × Sol-Ark 5K Single-Phase Hybrid Solar Inverter\u003c\/strong\u003e5K-1P-N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 × Discover Energy AES RACKMOUNT Heated LiFePO₄ Batteries \u003c\/strong\u003e48-48-5120-H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOff Grid Solar System with Hybrid Inverter and Heated Lithium Battery Storage\u003c\/h3\u003e\n\u003cp class=\"uss-highlight\"\u003e\u003cstrong\u003eSolar Energy Independence | N-Type Bifacial Panels | Sol-Ark Hybrid Inverter | Discover Heated Lithium Batteries | Expandable Energy Storage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBuild a residential off grid solar system with this solar kit featuring Philadelphia Solar bifacial panels, a Sol-Ark hybrid inverter, and Discover Energy AES RACKMOUNT heated lithium batteries.\u003c\/p\u003e\n\u003cp\u003eDesigned for homeowners exploring off grid solar power, energy independence, and residential battery storage, this equipment bundle combines solar electricity generation with rechargeable lithium battery technology.\u003c\/p\u003e\n\u003cp\u003eThe Philadelphia Solar panels generate electricity during daylight hours, while the Sol-Ark hybrid inverter supports solar power conversion and compatible battery charging. The Discover heated lithium batteries provide energy storage for later use, including periods when sunlight is unavailable.\u003c\/p\u003e\n\u003cp\u003eWhether you're planning a residential off grid solar installation, expanding an existing solar battery system, or designing backup power for essential household loads, this kit provides the primary components for a customized solar energy solution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation note:\u003c\/strong\u003e Independent off grid operation requires a compatible inverter and battery configuration, appropriate electrical protection, and site-specific system design. Additional equipment may be required.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar power generation:\u003c\/strong\u003e Provides photovoltaic modules for a properly designed off grid solar system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN-type bifacial technology:\u003c\/strong\u003e Supports efficient electricity generation with potential additional production from reflected sunlight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHybrid inverter:\u003c\/strong\u003e Supports photovoltaic input management, compatible battery charging, and energy management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated lithium batteries:\u003c\/strong\u003e Integrated heating helps support charging during colder conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiFePO₄ chemistry:\u003c\/strong\u003e Provides rechargeable battery storage with favorable thermal stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced battery management:\u003c\/strong\u003e Integrated BMS technology monitors battery operating conditions and provides protective functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar self-consumption:\u003c\/strong\u003e Supports storing available solar electricity for later household use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable storage:\u003c\/strong\u003e Discover AES RACKMOUNT batteries support approved multi-battery configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery communication:\u003c\/strong\u003e LYNK technology supports integration with approved inverter equipment using compatible accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup power potential:\u003c\/strong\u003e Supports selected electrical loads when installed as part of an approved backup energy system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePhiladelphia Solar N-Type Bifacial Solar Panels\u003c\/h2\u003e\n\u003cp\u003ePhiladelphia Solar NEXUS bifacial modules feature N-type monocrystalline half-cell technology designed for efficient photovoltaic generation and dependable outdoor performance.\u003c\/p\u003e\n\u003cp\u003eThe bifacial design allows sunlight to reach the solar cells from both the front and rear surfaces, creating the potential for additional electricity generation from reflected light.\u003c\/p\u003e\n\u003cp\u003eThese solar panels are suitable for properly designed residential rooftop and ground-mounted installations, including off grid solar applications.\u003c\/p\u003e\n\u003ch3\u003eSolar Panel Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eN-type monocrystalline cell technology.\u003c\/li\u003e\n\u003cli\u003eBifacial solar power generation.\u003c\/li\u003e\n\u003cli\u003eHalf-cell architecture designed to reduce mismatch losses.\u003c\/li\u003e\n\u003cli\u003eDurable construction for outdoor exposure.\u003c\/li\u003e\n\u003cli\u003eAnti-PID design features.\u003c\/li\u003e\n\u003cli\u003eManufacturer-backed product and performance warranties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBenefits of Bifacial Solar Technology\u003c\/h3\u003e\n\u003cp\u003eBifacial solar panels can generate additional electricity when reflected sunlight reaches the rear surface of the module.\u003c\/p\u003e\n\u003cp\u003eThis can be particularly beneficial for elevated arrays, ground-mounted installations, and locations with reflective surfaces beneath the panels.\u003c\/p\u003e\n\u003cp\u003eActual energy production depends on sunlight conditions, installation height, shading, surface reflectivity, and mounting configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSol-Ark Hybrid Inverter for Solar and Battery Storage\u003c\/h2\u003e\n\u003cp\u003eThe Sol-Ark hybrid inverter provides central power conversion and energy management functions for this solar equipment package.\u003c\/p\u003e\n\u003cp\u003eIt accepts compatible photovoltaic inputs, supports battery charging, and delivers AC electricity for appropriately configured electrical loads.\u003c\/p\u003e\n\u003cp\u003eThe inverter offers supported grid-interactive and battery operating modes, monitoring connectivity, and generator integration features.\u003c\/p\u003e\n\u003ch3\u003eHybrid Inverter Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated MPPT control:\u003c\/strong\u003e Helps optimize solar generation from compatible photovoltaic strings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHybrid operation:\u003c\/strong\u003e Supports solar generation and battery integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery charging:\u003c\/strong\u003e Provides configurable charging functions for supported lithium batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy management:\u003c\/strong\u003e Supports configurable operating modes for solar generation and storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Provides compatible network monitoring capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator integration:\u003c\/strong\u003e Supports appropriate generator applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical protection:\u003c\/strong\u003e Includes inverter monitoring and safety functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical design note:\u003c\/strong\u003e This inverter uses a single-phase AC output configuration. Confirm compatibility with the intended household loads and electrical service before installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eOff Grid Solar Power for Residential Applications\u003c\/h2\u003e\n\u003cp\u003eAn off grid solar system generates electricity from solar panels and stores available energy in batteries for use when sunlight is limited or unavailable.\u003c\/p\u003e\n\u003cp\u003eThis solar and battery equipment package brings together the primary components commonly used in residential off grid solar installations: photovoltaic panels, a hybrid inverter, and rechargeable lithium battery storage.\u003c\/p\u003e\n\u003cp\u003eWhen properly designed with compatible equipment, an off grid solar system can provide electricity for selected household loads without depending on continuous utility power.\u003c\/p\u003e\n\u003ch3\u003eBenefits of an Off Grid Solar System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGreater energy independence:\u003c\/strong\u003e Generate and store electricity for use without relying exclusively on utility power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar battery storage:\u003c\/strong\u003e Store available solar energy for evening use and periods of reduced sunlight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHybrid inverter technology:\u003c\/strong\u003e Manage solar generation and compatible battery charging through one inverter platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated lithium batteries:\u003c\/strong\u003e Support battery charging in colder installation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable storage:\u003c\/strong\u003e Plan for additional compatible battery capacity as energy needs increase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible applications:\u003c\/strong\u003e Suitable for properly designed residential solar storage and backup energy projects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlanning Your Off Grid Solar Installation\u003c\/h3\u003e\n\u003cp\u003eA successful off grid solar system requires more than selecting solar panels, an inverter, and batteries. The system must be sized for daily electricity consumption, peak electrical loads, seasonal sunlight availability, and the desired amount of stored energy.\u003c\/p\u003e\n\u003cp\u003eFor year-round off grid operation, additional solar generation, battery capacity, or generator support may be necessary.\u003c\/p\u003e\n\u003cp\u003eThe components in this package must be evaluated together to confirm compatibility and suitability for the intended installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDiscover AES RACKMOUNT Heated Lithium Battery Storage\u003c\/h2\u003e\n\u003cp\u003eThe Discover Energy AES RACKMOUNT heated battery platform provides rechargeable lithium iron phosphate energy storage for compatible residential solar and stationary power systems.\u003c\/p\u003e\n\u003cp\u003eEach battery features integrated heating, advanced battery management, high-current performance, and a compact rackmount design.\u003c\/p\u003e\n\u003cp\u003eUsing two battery modules increases available storage capacity while retaining the modular design of the AES RACKMOUNT platform.\u003c\/p\u003e\n\u003ch3\u003eDiscover Battery Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated heating:\u003c\/strong\u003e Helps support charging during colder conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiFePO₄ chemistry:\u003c\/strong\u003e Provides rechargeable lithium energy storage for stationary applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced BMS:\u003c\/strong\u003e Monitors operating conditions and provides protective controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-current capability:\u003c\/strong\u003e Supports substantial charging and discharging demands within manufacturer limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRackmount construction:\u003c\/strong\u003e Provides organized installation options for compatible battery racks and enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular expansion:\u003c\/strong\u003e Supports approved multi-battery configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLYNK communication:\u003c\/strong\u003e Supports integration with approved inverter systems using compatible communication equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated circuit protection:\u003c\/strong\u003e Includes battery-side electrical protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh energy efficiency:\u003c\/strong\u003e Designed to minimize charging and discharging losses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIntegrated Battery Heating for Cold-Weather Charging\u003c\/h2\u003e\n\u003cp\u003eLithium batteries can have charging restrictions at low temperatures. Discover's heated AES RACKMOUNT model includes an integrated heating system designed to help bring the battery into an appropriate charging temperature range.\u003c\/p\u003e\n\u003cp\u003eThis feature can be particularly useful for protected battery installation spaces that experience seasonal temperature changes.\u003c\/p\u003e\n\u003ch3\u003eHeated Battery Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports charging readiness during colder conditions.\u003c\/li\u003e\n\u003cli\u003eHelps manage battery temperature for supported charging operations.\u003c\/li\u003e\n\u003cli\u003eWorks with the integrated BMS to help protect battery cells.\u003c\/li\u003e\n\u003cli\u003eProvides additional flexibility when planning a protected installation.\u003c\/li\u003e\n\u003cli\u003eReduces reliance on ambient room heating alone.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation note:\u003c\/strong\u003e Integrated heating does not make the batteries weatherproof. They must be installed in a protected environment that meets manufacturer requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAdvanced Battery Management and LYNK Communication\u003c\/h2\u003e\n\u003cp\u003eDiscover AES RACKMOUNT batteries include intelligent battery management systems designed to monitor operating conditions and protect the lithium battery cells.\u003c\/p\u003e\n\u003cp\u003eThe batteries feature LYNK communication ports for integration with compatible external communication equipment.\u003c\/p\u003e\n\u003cp\u003eThe optional Discover LYNK II Gateway supports advanced communication with selected inverter-chargers, including supported Sol-Ark models.\u003c\/p\u003e\n\u003ch3\u003eBattery Management Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBattery state monitoring.\u003c\/li\u003e\n\u003cli\u003eTemperature monitoring.\u003c\/li\u003e\n\u003cli\u003eCharge and discharge protection.\u003c\/li\u003e\n\u003cli\u003eCell balancing.\u003c\/li\u003e\n\u003cli\u003eCompatible inverter communication.\u003c\/li\u003e\n\u003cli\u003eSupported battery diagnostics.\u003c\/li\u003e\n\u003cli\u003eCoordinated charging control with approved equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility note:\u003c\/strong\u003e The LYNK II Gateway is sold separately. Confirm the exact Sol-Ark inverter model, supported firmware, and required communication configuration before installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eExpandable Lithium Battery Storage\u003c\/h2\u003e\n\u003cp\u003eThe Discover AES RACKMOUNT platform is designed for modular battery storage expansion.\u003c\/p\u003e\n\u003cp\u003eCompatible battery modules can be combined using approved electrical protection, battery racks, and communication equipment.\u003c\/p\u003e\n\u003cp\u003eThis allows homeowners to plan for additional energy storage capacity as their needs change.\u003c\/p\u003e\n\u003cp\u003eAll battery expansion must follow Discover's approved installation requirements, including battery matching, wiring, communication, and enclosure specifications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSolar Self-Consumption and Backup Energy Applications\u003c\/h2\u003e\n\u003cp\u003eThis equipment package combines solar electricity generation and rechargeable lithium battery storage for compatible residential energy applications.\u003c\/p\u003e\n\u003cp\u003eWith an approved inverter and battery configuration, homeowners may be able to prioritize solar self-consumption and manage selected household loads using stored energy.\u003c\/p\u003e\n\u003ch3\u003ePotential Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGenerate electricity from residential solar panels.\u003c\/li\u003e\n\u003cli\u003eStore available solar energy for later consumption.\u003c\/li\u003e\n\u003cli\u003eReduce reliance on utility electricity during supported operating periods.\u003c\/li\u003e\n\u003cli\u003eMonitor solar generation and inverter operation.\u003c\/li\u003e\n\u003cli\u003ePlan for future storage expansion.\u003c\/li\u003e\n\u003cli\u003eSupport selected backup circuits with an approved installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual performance and electricity savings depend on utility rates, solar production, household loads, battery settings, and system configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential off grid solar system projects.\u003c\/li\u003e\n\u003cli\u003eHome solar and lithium battery storage installations.\u003c\/li\u003e\n\u003cli\u003eSolar self-consumption systems.\u003c\/li\u003e\n\u003cli\u003eHybrid solar energy projects.\u003c\/li\u003e\n\u003cli\u003eBattery storage in protected spaces with seasonal temperature changes.\u003c\/li\u003e\n\u003cli\u003eProfessionally designed essential-load backup systems.\u003c\/li\u003e\n\u003cli\u003eExpandable residential lithium battery storage.\u003c\/li\u003e\n\u003cli\u003eResidential energy management projects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003cdiv class=\"uss-spec-wrap\"\u003e\n\u003ctable class=\"uss-specs\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr class=\"section\"\u003e\n\u003ctd colspan=\"2\"\u003eSOLAR KIT OVERVIEW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit Type\u003c\/td\u003e\n\u003ctd\u003eResidential Solar and Battery Storage Equipment Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Solar Array Capacity\u003c\/td\u003e\n\u003ctd\u003e5,400W \/ 5.4kW DC (STC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Nominal Battery Capacity\u003c\/td\u003e\n\u003ctd\u003e10.24kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolar Panel Quantity\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Quantity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"section\"\u003e\n\u003ctd colspan=\"2\"\u003ePHILADELPHIA SOLAR PANEL SPECIFICATIONS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003ePhiladelphia Solar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ MPN\u003c\/td\u003e\n\u003ctd\u003ePS-MNB108(HCBF)-450W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e450W per Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Technology\u003c\/td\u003e\n\u003ctd\u003eN-Type Monocrystalline, Half-Cell, Bifacial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Voltage (Vmp)\u003c\/td\u003e\n\u003ctd\u003e33.51V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Current (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.44A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Circuit Voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e38.84V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.47A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum System Voltage\u003c\/td\u003e\n\u003ctd\u003e1,500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Series Fuse\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"section\"\u003e\n\u003ctd colspan=\"2\"\u003eSOL-ARK HYBRID INVERTER SPECIFICATIONS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSol-Ark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ MPN\u003c\/td\u003e\n\u003ctd\u003e5K-1P-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Phase Hybrid Solar Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous AC Output\u003c\/td\u003e\n\u003ctd\u003e4,800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Output\u003c\/td\u003e\n\u003ctd\u003e120V Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC Output Current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV Input Power\u003c\/td\u003e\n\u003ctd\u003e10,400W STC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV Input Voltage\u003c\/td\u003e\n\u003ctd\u003e500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal PV Voltage Range\u003c\/td\u003e\n\u003ctd\u003e150–425V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Startup Voltage\u003c\/td\u003e\n\u003ctd\u003e125V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Trackers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV Input Current per MPPT\u003c\/td\u003e\n\u003ctd\u003e26A; Self-Limiting at 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inverter Efficiency\u003c\/td\u003e\n\u003ctd\u003e97.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Battery Voltage\u003c\/td\u003e\n\u003ctd\u003e48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Operating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e40–60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Battery Charge\/Discharge Current\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eCANBus, RS485, Wi-Fi, LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ NEMA 3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"section\"\u003e\n\u003ctd colspan=\"2\"\u003eDISCOVER ENERGY BATTERY SPECIFICATIONS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDiscover Energy Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAES RACKMOUNT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ MPN\u003c\/td\u003e\n\u003ctd\u003e48-48-5120-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eHeated Rackmount Lithium Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Chemistry\u003c\/td\u003e\n\u003ctd\u003eLithium Iron Phosphate (LiFePO₄)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e51.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Energy per Battery\u003c\/td\u003e\n\u003ctd\u003e5.12kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombined Nominal Energy\u003c\/td\u003e\n\u003ctd\u003e10.24kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity per Battery\u003c\/td\u003e\n\u003ctd\u003e100Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombined Rated Capacity\u003c\/td\u003e\n\u003ctd\u003e200Ah, Parallel Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsable Depth of Discharge\u003c\/td\u003e\n\u003ctd\u003e100%, Subject to Manufacturer Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current (1 Hour), per Battery\u003c\/td\u003e\n\u003ctd\u003e95A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS Peak Discharge, per Battery\u003c\/td\u003e\n\u003ctd\u003e218A RMS for 3 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Breaker, per Battery\u003c\/td\u003e\n\u003ctd\u003eDual 100A, 2-Pole Ganged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Terminals\u003c\/td\u003e\n\u003ctd\u003eAmphenol SurLok Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Heating\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Operating Range\u003c\/td\u003e\n\u003ctd\u003e-17°C to +8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Temperature Range\u003c\/td\u003e\n\u003ctd\u003e+4°C to +52°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarging Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-17°C to +52°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Form Factor\u003c\/td\u003e\n\u003ctd\u003e19-Inch Rackmount, 3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions per Battery\u003c\/td\u003e\n\u003ctd\u003e497 × 439 × 133.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Battery\u003c\/td\u003e\n\u003ctd\u003e44kg \/ 97lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eLYNK Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Communication Gateway\u003c\/td\u003e\n\u003ctd\u003eDiscover LYNK II Gateway, MPN 950-0025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e10 Years, Subject to Terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory Standards\u003c\/td\u003e\n\u003ctd\u003eUL 1973, UL 9540A, UL 9540, IEC 62619 and UN 38.3 Marked Pending in Supplied Datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"section\"\u003e\n\u003ctd colspan=\"2\"\u003eSYSTEM COMPATIBILITY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter\/Battery Voltage Compatibility\u003c\/td\u003e\n\u003ctd\u003ePublished Operating Ranges Overlap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClosed-Loop Battery Communication\u003c\/td\u003e\n\u003ctd\u003eExact 5K-1P-N Compatibility Requires Confirmation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLYNK II Gateway\u003c\/td\u003e\n\u003ctd\u003eNot Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete System UL 9540 Listing\u003c\/td\u003e\n\u003ctd\u003eNot Established for This Exact Combination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charge\/Discharge Settings\u003c\/td\u003e\n\u003ctd\u003eMust Follow Approved Battery Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV String Configuration\u003c\/td\u003e\n\u003ctd\u003eInstaller-Designed Within Inverter Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eSystem Compatibility and Installation Requirements\u003c\/h2\u003e\n\u003cp\u003eThis equipment package combines components intended for residential solar generation, hybrid power conversion, and rechargeable battery storage.\u003c\/p\u003e\n\u003cp\u003eDiscover AES RACKMOUNT batteries support integration with selected Sol-Ark inverter-chargers through appropriate communication equipment. The exact inverter model supplied in this kit must be confirmed as supported before installation.\u003c\/p\u003e\n\u003cp\u003eBoth battery modules must be connected using an approved parallel configuration with suitable electrical protection, matching cables, and communication equipment.\u003c\/p\u003e\n\u003ch3\u003eBefore Installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the exact inverter and battery pairing is supported.\u003c\/li\u003e\n\u003cli\u003eVerify whether the Discover LYNK II Gateway is required.\u003c\/li\u003e\n\u003cli\u003eConfirm supported firmware and battery communication settings.\u003c\/li\u003e\n\u003cli\u003eVerify applicable energy storage system certifications.\u003c\/li\u003e\n\u003cli\u003eConfigure inverter charging and discharging settings within battery limits.\u003c\/li\u003e\n\u003cli\u003eDesign photovoltaic strings for local environmental conditions.\u003c\/li\u003e\n\u003cli\u003eConfirm inverter AC output suitability for intended loads.\u003c\/li\u003e\n\u003cli\u003eProvide compatible battery cables and mating connectors.\u003c\/li\u003e\n\u003cli\u003eUse approved parallel battery connection methods.\u003c\/li\u003e\n\u003cli\u003eSelect appropriately rated fuses, breakers, and disconnects.\u003c\/li\u003e\n\u003cli\u003eProvide compatible solar mounting and rapid shutdown equipment.\u003c\/li\u003e\n\u003cli\u003eInstall batteries in a protected environment.\u003c\/li\u003e\n\u003cli\u003eFollow applicable electrical codes and utility requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Equipment Required\u003c\/h3\u003e\n\u003cp\u003eThis package includes the solar panels, hybrid inverter, and batteries listed above. The following are not included unless expressly specified:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSolar panel mounting and racking hardware.\u003c\/li\u003e\n\u003cli\u003ePV extension cables and field wiring.\u003c\/li\u003e\n\u003cli\u003eBattery power cables and mating connectors.\u003c\/li\u003e\n\u003cli\u003eBattery rack, enclosure, or stacking brackets.\u003c\/li\u003e\n\u003cli\u003eApproved battery parallel connection equipment.\u003c\/li\u003e\n\u003cli\u003eDiscover LYNK II Gateway.\u003c\/li\u003e\n\u003cli\u003eRequired disconnects, breakers, and overcurrent protection.\u003c\/li\u003e\n\u003cli\u003eRapid shutdown equipment where applicable.\u003c\/li\u003e\n\u003cli\u003eElectrical distribution and transfer equipment.\u003c\/li\u003e\n\u003cli\u003eInstallation labor, engineering, and permitting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"uss-faq\"\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan this kit be used as an off grid solar system?\u003c\/summary\u003e\n\u003cp\u003eThe equipment is intended for solar generation and battery storage applications. Off grid operation depends on confirming compatibility between the Sol-Ark inverter and Discover batteries, as well as completing the required electrical system design.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is included in this off grid solar kit?\u003c\/summary\u003e\n\u003cp\u003eThe kit includes Philadelphia Solar bifacial panels, a Sol-Ark hybrid inverter, and two Discover AES RACKMOUNT heated lithium batteries. Mounting, wiring, communication equipment, and installation accessories are sold separately.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan an off grid solar system power a house?\u003c\/summary\u003e\n\u003cp\u003eYes, a properly sized off grid solar system can supply residential electricity. This particular kit must be evaluated against household energy consumption, peak loads, and seasonal solar production to determine which loads it can support.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow much battery storage do I need for an off grid solar system?\u003c\/summary\u003e\n\u003cp\u003eBattery storage requirements depend on daily electricity consumption, overnight loads, expected periods without sunlight, and the desired backup duration. Additional batteries may be required for full-time off grid living.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan this off grid solar kit operate without utility electricity?\u003c\/summary\u003e\n\u003cp\u003ePotentially, when installed with an approved inverter and battery configuration and all necessary electrical equipment. The exact system must be verified before it is represented as capable of independent operation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eAre the Discover batteries heated?\u003c\/summary\u003e\n\u003cp\u003eYes. Both batteries are the heated AES RACKMOUNT model with integrated battery heating for supported low-temperature charging conditions.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the batteries be installed outdoors?\u003c\/summary\u003e\n\u003cp\u003eThe battery modules are not weatherproof. They require a suitable protected installation environment or approved enclosure.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes each battery include a BMS?\u003c\/summary\u003e\n\u003cp\u003eYes. Each battery includes an advanced battery management system that monitors operating conditions and provides protective functions.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eAre the Discover batteries compatible with Sol-Ark inverters?\u003c\/summary\u003e\n\u003cp\u003eDiscover provides integration guidance for selected Sol-Ark models. The exact inverter model supplied in this kit must be confirmed as supported before installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs a Discover LYNK II Gateway required?\u003c\/summary\u003e\n\u003cp\u003eAdvanced closed-loop communication with supported inverters may require the Discover LYNK II Gateway. Confirm communication requirements for the specific inverter.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs the LYNK II Gateway included?\u003c\/summary\u003e\n\u003cp\u003eNo. The LYNK II Gateway is not included in the listed kit components.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan more batteries be added later?\u003c\/summary\u003e\n\u003cp\u003eThe AES RACKMOUNT platform supports approved multi-battery configurations. Expansion requires compatible electrical protection, communication equipment, and installation design.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eAre the solar panels bifacial?\u003c\/summary\u003e\n\u003cp\u003eYes. Philadelphia Solar's bifacial modules can generate electricity from sunlight reaching both the front and rear surfaces.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the solar panels be roof mounted?\u003c\/summary\u003e\n\u003cp\u003eYes. They can be installed using compatible rooftop mounting systems and approved mounting methods.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the panels be ground mounted?\u003c\/summary\u003e\n\u003cp\u003eYes. Ground mounting is possible with suitable structural support and electrical installation methods.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the system store solar electricity for nighttime use?\u003c\/summary\u003e\n\u003cp\u003eThat is an intended application of the equipment. Actual operation requires confirmed inverter and battery compatibility and appropriate settings.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan this kit provide backup power during an outage?\u003c\/summary\u003e\n\u003cp\u003ePotentially, when configured as an approved backup system with suitable electrical equipment and confirmed battery compatibility.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan this kit power an entire house?\u003c\/summary\u003e\n\u003cp\u003eIt is better evaluated for selected residential loads. Whole-home suitability depends on electrical service configuration, connected loads, and system design.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the kit include solar mounting hardware?\u003c\/summary\u003e\n\u003cp\u003eNo. Solar mounting and racking hardware must be selected separately.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the kit include battery cables?\u003c\/summary\u003e\n\u003cp\u003eNo. Compatible battery cables and mating connectors must be selected separately unless specifically added to the package.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eAre the batteries UL 9540 certified?\u003c\/summary\u003e\n\u003cp\u003eThe supplied Discover datasheet marks UL 9540 and related standards as pending. Confirm current certification status and approved system combinations before installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I monitor the system remotely?\u003c\/summary\u003e\n\u003cp\u003eThe Sol-Ark inverter supports network monitoring. Battery data integration depends on the approved communication configuration and required accessories.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs professional installation recommended?\u003c\/summary\u003e\n\u003cp\u003eYes. Professional system design and installation are recommended to ensure electrical compatibility, safe operation, and compliance with applicable codes.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e","brand":"Sol-Ark","offers":[{"title":"Default Title","offer_id":53323845665066,"sku":"USSSP202-1425","price":7539.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/3408\/1340\/files\/Off_Grid_Kit_12_panels_-_v2.png?v=1793116968","url":"https:\/\/ussolarsupplier.com\/products\/5-4kw-off-grid-solar-kit-with-sol-ark-5k-10-24kwh-discover-batteries","provider":"US Solar Supplier","version":"1.0","type":"link"}